  Enter 2019, growing to update and develop market applications and demand on the network and even server hosting requirements, number and size of growing conditions in different areas of the room is the range for all users to consider, such as 1, the engine room of the power supply device, in the event off situation of electricity, how to save; 2, UPS; 3, air-conditioning equipment, whether the thermostat; 4, fire; 5, security surveillance. These systems and devices can run the computer system and various units of the network, it provides the necessary data security and reliable protection.
  
  Today it is under the full name UPS- UPS room power environment integrated monitoring system, it is stable and safe electricity engine room protection, choose the right brand and quality, in order to give protection to the engine room of electricity around the clock, so the matching engine room ups when the power supply, which a few factors to consider it?
  
1, the actual load capacity
  it is the most important factor in determining the size of the power supply capacity, its output must meet or exceed the load capacity required in order to ensure normal power supply.
  
2, type of load
  different types of loads, different proportions of the active and reactive power, the UPS must provide sufficient active and reactive power to the load at the same time, the actual output is limited by the type of load capacity.
  
3, UPS power capacity utilization
  
4, ambient conditions
  1) .UPS main battery and the working environment should avoid direct sunlight, and away from other radiant heat sources, clean, cool, dry, ventilated to avoid harmful dust.
  2) .UPS host ambient temperature range can work in claim 0 ℃ -30 ℃, but the high temperature requirements for UPS battery, UPS battery required standard ambient temperature is 25 ℃, preferably not exceed 15 ℃ -30 ℃ range .
  
5, UPS type and actual load capacity
  
6, the potential demand expansion device
  (1) Configuration UPS capacity should consider future expansion needs equipment, leave some margin, future load increases, the UPS will not purchase again.
  (2) When configuring the UPS input and output power distribution equipment, cables and open space should leave some headroom for future expansion.
  
  In order to ensure long-term stable operation of UPS, UPS is working properly grasp, to understand the ground through UPS UPS monitoring operational parameters, including: input voltage, output voltage, current and frequency, output apparent power, active power and power factor, load factor, the temperature of the power device, the battery discharge current and charging current, the battery capacity and power backup time, fault location and time records. Work status and parameters of the rectifier, inverter, battery, bypass, load and other real-time monitoring of UPS, UPS comes through intelligent communication interfaces and communication protocols, real-time, comprehensive diagnostic UPS operating conditions, modify the UPS parameters set by the network remotely. Unified remote monitoring, management, significant cost savings in all aspects.