PLC通信协议【西门子】S7系列协议初始化报文

s7-200

发送:03 00 00 16 11 e0 00 00 00 01 00 c1 02 4d 57 c2 02 4d 57 c0 01 09
返回:03 00 00 16 11 d0 00 01 00 0c 00 c1 02 4d 57 c2 02 4d 57 c0 01 09
发送:03 00 00 19 02 f0 80 32 01 00 00 00 00 00 08 00 00 f0 00 00 01 00 01 03 c0
返回:03 00 00 1b 02 f0 80 32 03 00 00 00 00 00 08 00 00 00 00 f0 01 00 01 00 f0 00 f0

s7-200smart
s7-200smart只需注意倒数第四项Source TSAP和倒数第一项Destination TSAP,分别代表PLC参数中的localTASP和RemotTASP参数,默认为 0x0200 及 0x0201

发送:03 00 00 16 11 E0 00 00 00 01 00 C0 01 09 C1 02 02 00 C2 02 02 01
返回:03 00 00 16 11 D0 00 01 00 08 00 C0 01 09 C1 02 02 00 C2 02 02 01
发送:03 00 00 19 02 F0 80 32 01 00 00 00 38 00 08 00 00 F0 00 00 01 00 01 00 F0
返回:03 00 00 1B 02 F0 80 32 03 00 00 00 00 00 08 00 00 00 00 F0 01 00 01 00 F0 00 F0 

s7-300

发送:03 00 00 16 11 e0 00 00 00