MegaCli使用

  • 0.前沿介绍
  • 1. lsscsi -s 查看盘符对应关系
  • 2. 查看物理槽位占用情况
  • 3.查看适配器(控制器)个数
  • 4.查看控制器序号,名称,序列号
  • 5.查看所有逻辑层次磁盘详细信息
  • 6.查看所有物理层次磁盘详细信息
  • 7.查看raid信息(对应到target id,即逻辑磁盘):
  • 8. 查看是raid还是JBOD
  • 9.查看物理磁盘和逻辑磁盘对应关系
  • 10.附录:查询物理和逻辑所有磁盘信息

0.前沿介绍

  • PD:物理的磁盘信息
  • LD:逻辑的磁盘信息
  • MegaCli64 参数对大小写不敏感
  • a:Adapter,适配器,适配器即为阵列卡控制器,以下以‘控制器’简称
  • -LdPdInfo:物理和逻辑的信息

MegaCli64不是所有的磁盘阵列卡都可以使用,如果不支持,需要使用其他的工具,如storcli/percli等

1. lsscsi -s 查看盘符对应关系:
通过lsscsi查看磁盘情况,这里显示的是逻辑层的,比如sda实际上是二块盘组成的raid1.

The first entry on each line is the scsi_host,channel,target_number,LUN

[root@node-5 MegaCli]# lsscsi -s
[0:2:0:0]    disk    DELL     PERC H730P Mini  4.26  /dev/sda    299GB
[0:2:1:0]    disk    DELL     PERC H730P Mini  4.26  /dev/sdb    599GB
[0:2:2:0]    disk    DELL     PERC H730P Mini  4.26  /dev/sdc    599GB
[0:2:3:0]    disk    DELL     PERC H730P Mini  4.26  /dev/sdd    599GB
[0:2:4:0]    disk    DELL     PERC H730P Mini  4.26  /dev/sde    599GB
[0:2:5:0]    disk    DELL     PERC H730P Mini  4.26  /dev/sdf    599GB
[0:2:6:0]    disk    DELL     PERC H730P Mini  4.26  /dev/sdg    599GB
[0:2:7:0]    disk    DELL     PERC H730P Mini  4.26  /dev/sdh    599GB
[0:2:8:0]    disk    DELL     PERC H730P Mini  4.26  /dev/sdi    599GB
[0:2:9:0]    disk    DELL     PERC H730P Mini  4.26  /dev/sdj    599GB
[0:2:10:0]   disk    DELL     PERC H730P Mini  4.26  /dev/sdk    599GB
[0:2:11:0]   disk    DELL     PERC H730P Mini  4.26  /dev/sdl    599GB
[0:2:12:0]   disk    DELL     PERC H730P Mini  4.26  /dev/sdm    479GB
[0:2:13:0]   disk    DELL     PERC H730P Mini  4.26  /dev/sdn    479GB
[0:2:14:0]   disk    DELL     PERC H730P Mini  4.26  /dev/sdo    479GB
[root@node-5 MegaCli]# 

2. 查看物理槽位占用情况:

[root@node-5 MegaCli]# ./MegaCli64 -PDList -a0 | grep Slot
Slot Number: 0
Slot Number: 1
Slot Number: 2
Slot Number: 3
Slot Number: 4
Slot Number: 5
Slot Number: 6
Slot Number: 7
Slot Number: 8
Slot Number: 9
Slot Number: 10
Slot Number: 11
Slot Number: 12
Slot Number: 21
Slot Number: 22
Slot Number: 23

这里可以看到磁盘物理占用的槽位为16个,lsscsi显示共15条,是因为sda是raid1,占用2个槽位。

3.查看适配器(控制器)个数
适配器即为阵列卡控制器,以下以‘控制器’简称

[root@node-5 MegaCli]# ./MegaCli64 -adpCount                 
Controller Count: 1.
Exit Code: 0x01

4.查看控制器序号,名称,序列号

[root@node-5 MegaCli]# ./MegaCli64 -AdpAllInfo -Aall | grep -E "Adapter|Product Name|Serial"
Adapter #0
Product Name    : PERC H730P Mini
Serial No       : 64F01JN
Serial Debugger  : Present

5.查看所有逻辑层次磁盘详细信息
语法:MegaCli -LDInfo -Lx|-L0,1,2|-Lall -aN|-a0,1,2|-aALL

这里LD即Target Id;
[root@node-5 MegaCli]# ./MegaCli64 -LDInfo -L14 -a0
Adapter 0 -- Virtual Drive Information:
Virtual Drive: 14 (Target Id: 14)
Name                :
RAID Level          : Primary-0, Secondary-0, RAID Level Qualifier-0
Size                : 446.625 GB
Sector Size         : 512
Is VD emulated      : Yes
Parity Size         : 0
State               : Optimal
Strip Size          : 64 KB
Number Of Drives    : 1
Span Depth          : 1
Default Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU
Current Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU
Default Access Policy: Read/Write
Current Access Policy: Read/Write
Disk Cache Policy   : Disk's Default
Encryption Type     : None
Default Power Savings Policy: Controller Defined
Current Power Savings Policy: None
Can spin up in 1 minute: No
LD has drives that support T10 power conditions: No
LD's IO profile supports MAX power savings with cached writes: No
Bad Blocks Exist: No
PI type: No PI

Is VD Cached: No

6.查看所有物理层次磁盘详细信息
语法:MegaCli64 -PDlist -aALL

[root@node-5 MegaCli]# ./MegaCli64 -PDlist   -aALl                                 
Adapter #0
Enclosure Device ID: 32
Slot Number: 0
Drive's position: DiskGroup: 0, Span: 0, Arm: 0
Enclosure position: 1
Device Id: 0
WWN: 5000C50096E10F14
Sequence Number: 2
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SAS

Raw Size: 279.396 GB [0x22ecb25c Sectors]
Non Coerced Size: 278.896 GB [0x22dcb25c Sectors]
Coerced Size: 278.875 GB [0x22dc0000 Sectors]
Sector Size:  512
Logical Sector Size:  512
Physical Sector Size:  512
Firmware state: Online, Spun Up
Device Firmware Level: VT31
Shield Counter: 0
Successful diagnostics completion on :  N/A
SAS Address(0): 0x5000c50096e10f15
SAS Address(1): 0x0
Connected Port Number: 0(path0) 
Inquiry Data: SEAGATE ST300MP0005     VT31S7K11KGK            
FDE Capable: Not Capable
FDE Enable: Disable
Secured: Unsecured
Locked: Unlocked
Needs EKM Attention: No
Foreign State: None 
Device Speed: 12.0Gb/s 
Link Speed: 12.0Gb/s 
Media Type: Hard Disk Device
Drive Temperature :34C (93.20 F)
PI Eligibility:  Yes 
Number of bytes of user data in LBA: 512 
Drive is formatted for PI information:  Yes 
PI: PI with type 2
Port-0 :
Port status: Active
Port's Linkspeed: 12.0Gb/s 
Port-1 :
Port status: Active
Port's Linkspeed: 12.0Gb/s 
Drive has flagged a S.M.A.R.T alert : No

Enclosure Device ID: 32
Slot Number: 1
Drive's position: DiskGroup: 0, Span: 0, Arm: 1
Enclosure position: 1
Device Id: 1
WWN: 5000C50096E13580
Sequence Number: 2
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SAS

Raw Size: 279.396 GB [0x22ecb25c Sectors]
Non Coerced Size: 278.896 GB [0x22dcb25c Sectors]
Coerced Size: 278.875 GB [0x22dc0000 Sectors]
Sector Size:  512
Logical Sector Size:  512
Physical Sector Size:  512
Firmware state: Online, Spun Up
Device Firmware Level: VT31
Shield Counter: 0
Successful diagnostics completion on :  N/A
SAS Address(0): 0x5000c50096e13581
SAS Address(1): 0x0
Connected Port Number: 0(path0) 
Inquiry Data: SEAGATE ST300MP0005     VT31S7K11K9J            
FDE Capable: Not Capable
FDE Enable: Disable
Secured: Unsecured
Locked: Unlocked
Needs EKM Attention: No
Foreign State: None 
Device Speed: 12.0Gb/s 
Link Speed: 12.0Gb/s 
Media Type: Hard Disk Device
Drive Temperature :32C (89.60 F)
PI Eligibility:  Yes 
Number of bytes of user data in LBA: 512 
Drive is formatted for PI information:  Yes 
PI: PI with type 2
Port-0 :
Port status: Active
Port's Linkspeed: 12.0Gb/s 
Port-1 :
Port status: Active
Port's Linkspeed: 12.0Gb/s 
Drive has flagged a S.M.A.R.T alert : No

Enclosure Device ID: 32
Slot Number: 2
Drive's position: DiskGroup: 1, Span: 0, Arm: 0
Enclosure position: 1
Device Id: 2
WWN: 50000396B81B83B0
Sequence Number: 2
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SAS

Raw Size: 558.911 GB [0x45dd2fb0 Sectors]
Non Coerced Size: 558.411 GB [0x45cd2fb0 Sectors]
Coerced Size: 558.375 GB [0x45cc0000 Sectors]
Sector Size:  512
Logical Sector Size:  512
Physical Sector Size:  512
Firmware state: Online, Spun Up
Device Firmware Level: DK04
Shield Counter: 0
Successful diagnostics completion on :  N/A
SAS Address(0): 0x50000396b81b83b2
SAS Address(1): 0x0
Connected Port Number: 0(path0) 
Inquiry Data: TOSHIBA AL13SXB60EN     DK04Z5C0A04RFHRC        
FDE Capable: Not Capable
FDE Enable: Disable
Secured: Unsecured
Locked: Unlocked
Needs EKM Attention: No
Foreign State: None 
Device Speed: 12.0Gb/s 
Link Speed: 12.0Gb/s 
Media Type: Hard Disk Device
Drive Temperature :31C (87.80 F)
PI Eligibility:  Yes 
Number of bytes of user data in LBA: 512 
Drive is formatted for PI information:  Yes 
PI: PI with type 2
Port-0 :
Port status: Active
Port's Linkspeed: 12.0Gb/s 
Port-1 :
Port status: Active
Port's Linkspeed: 12.0Gb/s 
Drive has flagged a S.M.A.R.T alert : No
...
...

7.查看raid信息(对应到target id,即逻辑磁盘):

//RAID Level对应关系
RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0   RAID0
RAID Level : Primary-1, Secondary-0, RAID Level Qualifier-0   RAID1
RAID Level : Primary-5, Secondary-0, RAID Level Qualifier-3   RAID5
RAID Level : Primary-1, Secondary-3, RAID Level Qualifier-0   RAID10
//Raid卡磁盘缓存模式
[root@node-5 MegaCli]# ./MegaCli64 -LDGetProp -Cache -LALL -aALL

Adapter 0-VD 0(target id: 0): Cache Policy:WriteBack, ReadAhead, Direct, No Write Cache if bad BBU
Adapter 0-VD 1(target id: 1): Cache Policy:WriteBack, ReadAhead, Direct, No Write Cache if bad BBU
Adapter 0-VD 2(target id: 2): Cache Policy:WriteBack, ReadAhead, Direct, No Write Cache if bad BBU
Adapter 0-VD 3(target id: 3): Cache Policy:WriteBack, ReadAhead, Direct, No Write Cache if bad BBU
Adapter 0-VD 4(target id: 4): Cache Policy:WriteBack, ReadAhead, Direct, No Write Cache if bad BBU
Adapter 0-VD 5(target id: 5): Cache Policy:WriteBack, ReadAhead, Direct, No Write Cache if bad BBU
Adapter 0-VD 6(target id: 6): Cache Policy:WriteBack, ReadAhead, Direct, No Write Cache if bad BBU
Adapter 0-VD 7(target id: 7): Cache Policy:WriteBack, ReadAhead, Direct, No Write Cache if bad BBU
Adapter 0-VD 8(target id: 8): Cache Policy:WriteBack, ReadAhead, Direct, No Write Cache if bad BBU
Adapter 0-VD 9(target id: 9): Cache Policy:WriteBack, ReadAhead, Direct, No Write Cache if bad BBU
Adapter 0-VD 10(target id: 10): Cache Policy:WriteBack, ReadAhead, Direct, No Write Cache if bad BBU
Adapter 0-VD 11(target id: 11): Cache Policy:WriteBack, ReadAhead, Direct, No Write Cache if bad BBU
Adapter 0-VD 12(target id: 12): Cache Policy:WriteBack, ReadAhead, Direct, No Write Cache if bad BBU
Adapter 0-VD 13(target id: 13): Cache Policy:WriteBack, ReadAhead, Direct, No Write Cache if bad BBU
Adapter 0-VD 14(target id: 14): Cache Policy:WriteBack, ReadAhead, Direct, No Write Cache if bad BBU

Exit Code: 0x00
//Raid卡磁盘raid模式
[root@node-5 MegaCli]# ./MegaCli64 -ldinfo -LALL -aALL | grep -E "Target Id|RAID Level" 
Virtual Drive: 0 (Target Id: 0)
RAID Level          : Primary-1, Secondary-0, RAID Level Qualifier-0
Virtual Drive: 1 (Target Id: 1)
RAID Level          : Primary-0, Secondary-0, RAID Level Qualifier-0
Virtual Drive: 2 (Target Id: 2)
RAID Level          : Primary-0, Secondary-0, RAID Level Qualifier-0
Virtual Drive: 3 (Target Id: 3)
RAID Level          : Primary-0, Secondary-0, RAID Level Qualifier-0
Virtual Drive: 4 (Target Id: 4)
RAID Level          : Primary-0, Secondary-0, RAID Level Qualifier-0
Virtual Drive: 5 (Target Id: 5)
RAID Level          : Primary-0, Secondary-0, RAID Level Qualifier-0
Virtual Drive: 6 (Target Id: 6)
RAID Level          : Primary-0, Secondary-0, RAID Level Qualifier-0
Virtual Drive: 7 (Target Id: 7)
RAID Level          : Primary-0, Secondary-0, RAID Level Qualifier-0
Virtual Drive: 8 (Target Id: 8)
RAID Level          : Primary-0, Secondary-0, RAID Level Qualifier-0
Virtual Drive: 9 (Target Id: 9)
RAID Level          : Primary-0, Secondary-0, RAID Level Qualifier-0
Virtual Drive: 10 (Target Id: 10)
RAID Level          : Primary-0, Secondary-0, RAID Level Qualifier-0
Virtual Drive: 11 (Target Id: 11)
RAID Level          : Primary-0, Secondary-0, RAID Level Qualifier-0
Virtual Drive: 12 (Target Id: 12)
RAID Level          : Primary-0, Secondary-0, RAID Level Qualifier-0
Virtual Drive: 13 (Target Id: 13)
RAID Level          : Primary-0, Secondary-0, RAID Level Qualifier-0
Virtual Drive: 14 (Target Id: 14)
RAID Level          : Primary-0, Secondary-0, RAID Level Qualifier-0
[root@node-5 MegaCli]# 

8. 查看是raid还是JBOD

//Firmware state : Online, Spun Up 代表是raid
//Firmware state : JBOD 代表是JBOD
[root@node-5 MegaCli]# ./MegaCli64  -PDList -aAll | grep  -E "Raw Size|Firmware state|Slot"
Slot Number: 0
Raw Size: 279.396 GB [0x22ecb25c Sectors]
Firmware state: Online, Spun Up
Slot Number: 1
Raw Size: 279.396 GB [0x22ecb25c Sectors]
Firmware state: Online, Spun Up
Slot Number: 2
Raw Size: 558.911 GB [0x45dd2fb0 Sectors]
Firmware state: Online, Spun Up
Slot Number: 3
Raw Size: 558.911 GB [0x45dd2fb0 Sectors]
Firmware state: Online, Spun Up
Slot Number: 4
Raw Size: 558.911 GB [0x45dd2fb0 Sectors]
Firmware state: Online, Spun Up
Slot Number: 5
Raw Size: 558.911 GB [0x45dd2fb0 Sectors]
Firmware state: Online, Spun Up
Slot Number: 6
Raw Size: 558.911 GB [0x45dd2fb0 Sectors]
Firmware state: Online, Spun Up
Slot Number: 7
Raw Size: 558.911 GB [0x45dd2fb0 Sectors]
Firmware state: Online, Spun Up
Slot Number: 8
Raw Size: 558.911 GB [0x45dd2fb0 Sectors]
Firmware state: Online, Spun Up
Slot Number: 9
Raw Size: 558.911 GB [0x45dd2fb0 Sectors]
Firmware state: Online, Spun Up
Slot Number: 10
Raw Size: 558.911 GB [0x45dd2fb0 Sectors]
Firmware state: Online, Spun Up
Slot Number: 11
Raw Size: 558.911 GB [0x45dd2fb0 Sectors]
Firmware state: Online, Spun Up
Slot Number: 12
Raw Size: 558.911 GB [0x45dd2fb0 Sectors]
Firmware state: Online, Spun Up
Slot Number: 21
Raw Size: 447.130 GB [0x37e436b0 Sectors]
Firmware state: Online, Spun Up
Slot Number: 22
Raw Size: 447.130 GB [0x37e436b0 Sectors]
Firmware state: Online, Spun Up
Slot Number: 23
Raw Size: 447.130 GB [0x37e436b0 Sectors]
Firmware state: Online, Spun Up
[root@node-5 MegaCli]# 

9.查看物理磁盘和逻辑磁盘对应关系
语法:./MegaCli64 -LdPdInfo -aALL, 该命令是物理和逻辑查询的总和,信息相对比较全;
查看物理磁盘槽位。结合lsscsi 的target id进行判断。
这里‘Target Id’应该和lsscsi的[x:x:x:x] 第三个字段对应,这个应该可以确定,但没有证据支撑;另外如果节点有多个阵列卡,那么需要综合判断;

[root@node-5 MegaCli]# ./MegaCli64 -LdPdInfo -a0 | grep -iE "slot|Virtual Drive|PD|Raw Size|RAID Level"
Virtual Drive: 0 (Target Id: 0)
RAID Level          : Primary-1, Secondary-0, RAID Level Qualifier-0
Span: 0 - Number of PDs: 2 // 这里可以看到包括2块磁盘(RAID1)
PD: 0 Information //磁盘1
Slot Number: 0
PD Type: SAS
Raw Size: 279.396 GB [0x22ecb25c Sectors]
PD: 1 Information //磁盘2
Slot Number: 1
PD Type: SAS
Raw Size: 279.396 GB [0x22ecb25c Sectors]
Virtual Drive: 1 (Target Id: 1)
RAID Level          : Primary-0, Secondary-0, RAID Level Qualifier-0
Span: 0 - Number of PDs: 1
PD: 0 Information
Slot Number: 2
PD Type: SAS
Raw Size: 558.911 GB [0x45dd2fb0 Sectors]
Virtual Drive: 2 (Target Id: 2)
RAID Level          : Primary-0, Secondary-0, RAID Level Qualifier-0
Span: 0 - Number of PDs: 1
PD: 0 Information
Slot Number: 3
PD Type: SAS
Raw Size: 558.911 GB [0x45dd2fb0 Sectors]
Virtual Drive: 3 (Target Id: 3)
RAID Level          : Primary-0, Secondary-0, RAID Level Qualifier-0
Span: 0 - Number of PDs: 1
PD: 0 Information
Slot Number: 4
PD Type: SAS
Raw Size: 558.911 GB [0x45dd2fb0 Sectors]
Virtual Drive: 4 (Target Id: 4)
RAID Level          : Primary-0, Secondary-0, RAID Level Qualifier-0
Span: 0 - Number of PDs: 1
PD: 0 Information
Slot Number: 5
PD Type: SAS
Raw Size: 558.911 GB [0x45dd2fb0 Sectors]
Virtual Drive: 5 (Target Id: 5)
RAID Level          : Primary-0, Secondary-0, RAID Level Qualifier-0
Span: 0 - Number of PDs: 1
PD: 0 Information
Slot Number: 6
PD Type: SAS
Raw Size: 558.911 GB [0x45dd2fb0 Sectors]
Virtual Drive: 6 (Target Id: 6)
RAID Level          : Primary-0, Secondary-0, RAID Level Qualifier-0
Span: 0 - Number of PDs: 1
PD: 0 Information
Slot Number: 7
PD Type: SAS
Raw Size: 558.911 GB [0x45dd2fb0 Sectors]
Virtual Drive: 7 (Target Id: 7)
RAID Level          : Primary-0, Secondary-0, RAID Level Qualifier-0
Span: 0 - Number of PDs: 1
PD: 0 Information
Slot Number: 8
PD Type: SAS
Raw Size: 558.911 GB [0x45dd2fb0 Sectors]
Virtual Drive: 8 (Target Id: 8)
RAID Level          : Primary-0, Secondary-0, RAID Level Qualifier-0
Span: 0 - Number of PDs: 1
PD: 0 Information
Slot Number: 9
PD Type: SAS
Raw Size: 558.911 GB [0x45dd2fb0 Sectors]
Virtual Drive: 9 (Target Id: 9)
RAID Level          : Primary-0, Secondary-0, RAID Level Qualifier-0
Span: 0 - Number of PDs: 1
PD: 0 Information
Slot Number: 10
PD Type: SAS
Raw Size: 558.911 GB [0x45dd2fb0 Sectors]
Virtual Drive: 10 (Target Id: 10)
RAID Level          : Primary-0, Secondary-0, RAID Level Qualifier-0
Span: 0 - Number of PDs: 1
PD: 0 Information
Slot Number: 11
PD Type: SAS
Raw Size: 558.911 GB [0x45dd2fb0 Sectors]
Virtual Drive: 11 (Target Id: 11)
RAID Level          : Primary-0, Secondary-0, RAID Level Qualifier-0
Span: 0 - Number of PDs: 1
PD: 0 Information
Slot Number: 12
PD Type: SAS
Raw Size: 558.911 GB [0x45dd2fb0 Sectors]
Virtual Drive: 12 (Target Id: 12)
RAID Level          : Primary-0, Secondary-0, RAID Level Qualifier-0
Span: 0 - Number of PDs: 1
PD: 0 Information
Slot Number: 21
PD Type: SATA
Raw Size: 447.130 GB [0x37e436b0 Sectors]
Virtual Drive: 13 (Target Id: 13)
RAID Level          : Primary-0, Secondary-0, RAID Level Qualifier-0
Span: 0 - Number of PDs: 1
PD: 0 Information
Slot Number: 22
PD Type: SATA
Raw Size: 447.130 GB [0x37e436b0 Sectors]
Virtual Drive: 14 (Target Id: 14)
RAID Level          : Primary-0, Secondary-0, RAID Level Qualifier-0
Span: 0 - Number of PDs: 1
PD: 0 Information
Slot Number: 23
PD Type: SATA
Raw Size: 447.130 GB [0x37e436b0 Sectors]
[root@node-5 MegaCli]# 

10.附录:查询物理和逻辑所有磁盘信息

[root@node-5 MegaCli]# ./MegaCli64 -LdPdInfo -a0 | grep -iE "slot|Virtual Drive|PD|Raw Size|RAID Level"
Adapter #0

Number of Virtual Disks: 15
Virtual Drive: 0 (Target Id: 0)
Name                :
RAID Level          : Primary-1, Secondary-0, RAID Level Qualifier-0
Size                : 278.875 GB
Sector Size         : 512
Is VD emulated      : No
Mirror Data         : 278.875 GB
State               : Optimal
Strip Size          : 64 KB
Number Of Drives    : 2
Span Depth          : 1
Default Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU
Current Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU
Default Access Policy: Read/Write
Current Access Policy: Read/Write
Disk Cache Policy   : Disk's Default
Encryption Type     : None
Default Power Savings Policy: Controller Defined
Current Power Savings Policy: None
Can spin up in 1 minute: Yes
LD has drives that support T10 power conditions: Yes
LD's IO profile supports MAX power savings with cached writes: No
Bad Blocks Exist: No
PI type: No PI

Is VD Cached: No
Number of Spans: 1
Span: 0 - Number of PDs: 2

PD: 0 Information
Enclosure Device ID: 32
Slot Number: 0
Drive's position: DiskGroup: 0, Span: 0, Arm: 0
Enclosure position: 1
Device Id: 0
WWN: 5000C50096E10F14
Sequence Number: 2
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SAS

Raw Size: 279.396 GB [0x22ecb25c Sectors]
Non Coerced Size: 278.896 GB [0x22dcb25c Sectors]
Coerced Size: 278.875 GB [0x22dc0000 Sectors]
Sector Size:  512
Logical Sector Size:  512
Physical Sector Size:  512
Firmware state: Online, Spun Up
Device Firmware Level: VT31
Shield Counter: 0
Successful diagnostics completion on :  N/A
SAS Address(0): 0x5000c50096e10f15
SAS Address(1): 0x0
Connected Port Number: 0(path0) 
Inquiry Data: SEAGATE ST300MP0005     VT31S7K11KGK            
FDE Capable: Not Capable
FDE Enable: Disable
Secured: Unsecured
Locked: Unlocked
Needs EKM Attention: No
Foreign State: None 
Device Speed: 12.0Gb/s 
Link Speed: 12.0Gb/s 
Media Type: Hard Disk Device
Drive Temperature :34C (93.20 F)
PI Eligibility:  Yes 
Number of bytes of user data in LBA: 512 
Drive is formatted for PI information:  Yes 
PI: PI with type 2
Port-0 :
Port status: Active
Port's Linkspeed: 12.0Gb/s 
Port-1 :
Port status: Active
Port's Linkspeed: 12.0Gb/s 
Drive has flagged a S.M.A.R.T alert : No

PD: 1 Information
Enclosure Device ID: 32
Slot Number: 1
Drive's position: DiskGroup: 0, Span: 0, Arm: 1
Enclosure position: 1
Device Id: 1
WWN: 5000C50096E13580
Sequence Number: 2
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SAS

Raw Size: 279.396 GB [0x22ecb25c Sectors]
Non Coerced Size: 278.896 GB [0x22dcb25c Sectors]
Coerced Size: 278.875 GB [0x22dc0000 Sectors]
Sector Size:  512
Logical Sector Size:  512
Physical Sector Size:  512
Firmware state: Online, Spun Up
Device Firmware Level: VT31
Shield Counter: 0
Successful diagnostics completion on :  N/A
SAS Address(0): 0x5000c50096e13581
SAS Address(1): 0x0
Connected Port Number: 0(path0) 
Inquiry Data: SEAGATE ST300MP0005     VT31S7K11K9J           
FDE Capable: Not Capable
FDE Enable: Disable
Secured: Unsecured
Locked: Unlocked
Needs EKM Attention: No
Foreign State: None 
Device Speed: 12.0Gb/s 
Link Speed: 12.0Gb/s 
Media Type: Hard Disk Device
Drive Temperature :32C (89.60 F)
PI Eligibility:  Yes 
Number of bytes of user data in LBA: 512 
Drive is formatted for PI information:  Yes 
PI: PI with type 2
Port-0 :
Port status: Active
Port's Linkspeed: 12.0Gb/s 
Port-1 :
Port status: Active
Port's Linkspeed: 12.0Gb/s 
Drive has flagged a S.M.A.R.T alert : No

Virtual Drive: 1 (Target Id: 1)
Name                :
RAID Level          : Primary-0, Secondary-0, RAID Level Qualifier-0
Size                : 558.375 GB
Sector Size         : 512
Is VD emulated      : No
Parity Size         : 0
State               : Optimal
Strip Size          : 64 KB
Number Of Drives    : 1
Span Depth          : 1
Default Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU
Current Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU
Default Access Policy: Read/Write
Current Access Policy: Read/Write
Disk Cache Policy   : Disk's Default
Encryption Type     : None
Default Power Savings Policy: Controller Defined
Current Power Savings Policy: None
Can spin up in 1 minute: Yes
LD has drives that support T10 power conditions: Yes
LD's IO profile supports MAX power savings with cached writes: No
Bad Blocks Exist: No
PI type: No PI

Is VD Cached: No
Number of Spans: 1
Span: 0 - Number of PDs: 1

PD: 0 Information
Enclosure Device ID: 32
Slot Number: 2
Drive's position: DiskGroup: 1, Span: 0, Arm: 0
Enclosure position: 1
Device Id: 2
WWN: 50000396B81B83B0
Sequence Number: 2
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SAS

Raw Size: 558.911 GB [0x45dd2fb0 Sectors]
Non Coerced Size: 558.411 GB [0x45cd2fb0 Sectors]
Coerced Size: 558.375 GB [0x45cc0000 Sectors]
Sector Size:  512
Logical Sector Size:  512
Physical Sector Size:  512
Firmware state: Online, Spun Up
Device Firmware Level: DK04
Shield Counter: 0
Successful diagnostics completion on :  N/A
SAS Address(0): 0x50000396b81b83b2
SAS Address(1): 0x0
Connected Port Number: 0(path0) 
Inquiry Data: TOSHIBA AL13SXB60EN     DK04Z5C0A04RFHRC        
FDE Capable: Not Capable
FDE Enable: Disable
Secured: Unsecured
Locked: Unlocked
Needs EKM Attention: No
Foreign State: None 
Device Speed: 12.0Gb/s 
Link Speed: 12.0Gb/s 
Media Type: Hard Disk Device
Drive Temperature :30C (86.00 F)
PI Eligibility:  Yes 
Number of bytes of user data in LBA: 512 
Drive is formatted for PI information:  Yes 
PI: PI with type 2
Port-0 :
Port status: Active
Port's Linkspeed: 12.0Gb/s 
Port-1 :
Port status: Active
Port's Linkspeed: 12.0Gb/s 
Drive has flagged a S.M.A.R.T alert : No

Virtual Drive: 2 (Target Id: 2)
Name                :
RAID Level          : Primary-0, Secondary-0, RAID Level Qualifier-0
Size                : 558.375 GB
Sector Size         : 512
Is VD emulated      : No
Parity Size         : 0
State               : Optimal
Strip Size          : 64 KB
Number Of Drives    : 1
Span Depth          : 1
Default Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU
Current Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU
Default Access Policy: Read/Write
Current Access Policy: Read/Write
Disk Cache Policy   : Disk's Default
Encryption Type     : None
Default Power Savings Policy: Controller Defined
Current Power Savings Policy: None
Can spin up in 1 minute: Yes
LD has drives that support T10 power conditions: Yes
LD's IO profile supports MAX power savings with cached writes: No
Bad Blocks Exist: No
PI type: No PI

Is VD Cached: No
Number of Spans: 1
Span: 0 - Number of PDs: 1

PD: 0 Information
Enclosure Device ID: 32
Slot Number: 3
Drive's position: DiskGroup: 2, Span: 0, Arm: 0
Enclosure position: 1
Device Id: 3
WWN: 50000396B809270C
Sequence Number: 2
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SAS

Raw Size: 558.911 GB [0x45dd2fb0 Sectors]
Non Coerced Size: 558.411 GB [0x45cd2fb0 Sectors]
Coerced Size: 558.375 GB [0x45cc0000 Sectors]
Sector Size:  512
Logical Sector Size:  512
Physical Sector Size:  512
Firmware state: Online, Spun Up
Device Firmware Level: DK04
Shield Counter: 0
Successful diagnostics completion on :  N/A
SAS Address(0): 0x50000396b809270e
SAS Address(1): 0x0
Connected Port Number: 0(path0) 
Inquiry Data: TOSHIBA AL13SXB60EN     DK04Z550A0JTFHRC        
FDE Capable: Not Capable
FDE Enable: Disable
Secured: Unsecured
Locked: Unlocked
Needs EKM Attention: No
Foreign State: None 
Device Speed: 12.0Gb/s 
Link Speed: 12.0Gb/s 
Media Type: Hard Disk Device
Drive Temperature :30C (86.00 F)
PI Eligibility:  Yes 
Number of bytes of user data in LBA: 512 
Drive is formatted for PI information:  Yes 
PI: PI with type 2
Port-0 :
Port status: Active
Port's Linkspeed: 12.0Gb/s 
Port-1 :
Port status: Active
Port's Linkspeed: 12.0Gb/s 
Drive has flagged a S.M.A.R.T alert : No

Virtual Drive: 3 (Target Id: 3)
Name                :
RAID Level          : Primary-0, Secondary-0, RAID Level Qualifier-0
Size                : 558.375 GB
Sector Size         : 512
Is VD emulated      : No
Parity Size         : 0
State               : Optimal
Strip Size          : 64 KB
Number Of Drives    : 1
Span Depth          : 1
Default Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU
Current Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU
Default Access Policy: Read/Write
Current Access Policy: Read/Write
Disk Cache Policy   : Disk's Default
Encryption Type     : None
Default Power Savings Policy: Controller Defined
Current Power Savings Policy: None
Can spin up in 1 minute: Yes
LD has drives that support T10 power conditions: Yes
LD's IO profile supports MAX power savings with cached writes: No
Bad Blocks Exist: No
PI type: No PI

Is VD Cached: No
Number of Spans: 1
Span: 0 - Number of PDs: 1

PD: 0 Information
Enclosure Device ID: 32
Slot Number: 4
Drive's position: DiskGroup: 3, Span: 0, Arm: 0
Enclosure position: 1
Device Id: 4
WWN: 50000396B82387B8
Sequence Number: 2
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SAS

Raw Size: 558.911 GB [0x45dd2fb0 Sectors]
Non Coerced Size: 558.411 GB [0x45cd2fb0 Sectors]
Coerced Size: 558.375 GB [0x45cc0000 Sectors]
Sector Size:  512
Logical Sector Size:  512
Physical Sector Size:  512
Firmware state: Online, Spun Up
Device Firmware Level: DK04
Shield Counter: 0
Successful diagnostics completion on :  N/A
SAS Address(0): 0x50000396b82387ba
SAS Address(1): 0x0
Connected Port Number: 0(path0) 
Inquiry Data: TOSHIBA AL13SXB60EN     DK04Z5E0A0FMFHRC        
FDE Capable: Not Capable
FDE Enable: Disable
Secured: Unsecured
Locked: Unlocked
Needs EKM Attention: No
Foreign State: None 
Device Speed: 12.0Gb/s 
Link Speed: 12.0Gb/s 
Media Type: Hard Disk Device
Drive Temperature :30C (86.00 F)
PI Eligibility:  Yes 
Number of bytes of user data in LBA: 512 
Drive is formatted for PI information:  Yes 
PI: PI with type 2
Port-0 :
Port status: Active
Port's Linkspeed: 12.0Gb/s 
Port-1 :
Port status: Active
Port's Linkspeed: 12.0Gb/s 
Drive has flagged a S.M.A.R.T alert : No

Virtual Drive: 4 (Target Id: 4)
Name                :
RAID Level          : Primary-0, Secondary-0, RAID Level Qualifier-0
Size                : 558.375 GB
Sector Size         : 512
Is VD emulated      : No
Parity Size         : 0
State               : Optimal
Strip Size          : 64 KB
Number Of Drives    : 1
Span Depth          : 1
Default Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU
Current Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU
Default Access Policy: Read/Write
Current Access Policy: Read/Write
Disk Cache Policy   : Disk's Default
Encryption Type     : None
Default Power Savings Policy: Controller Defined
Current Power Savings Policy: None
Can spin up in 1 minute: Yes
LD has drives that support T10 power conditions: Yes
LD's IO profile supports MAX power savings with cached writes: No
Bad Blocks Exist: No
PI type: No PI

Is VD Cached: No
Number of Spans: 1
Span: 0 - Number of PDs: 1

PD: 0 Information
Enclosure Device ID: 32
Slot Number: 5
Drive's position: DiskGroup: 4, Span: 0, Arm: 0
Enclosure position: 1
Device Id: 5
WWN: 50000396A831F5DC
Sequence Number: 2
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SAS

Raw Size: 558.911 GB [0x45dd2fb0 Sectors]
Non Coerced Size: 558.411 GB [0x45cd2fb0 Sectors]
Coerced Size: 558.375 GB [0x45cc0000 Sectors]
Sector Size:  512
Logical Sector Size:  512
Physical Sector Size:  512
Firmware state: Online, Spun Up
Device Firmware Level: DK04
Shield Counter: 0
Successful diagnostics completion on :  N/A
SAS Address(0): 0x50000396a831f5de
SAS Address(1): 0x0
Connected Port Number: 0(path0) 
Inquiry Data: TOSHIBA AL13SXB60EN     DK04Y5X0A0JNFHRC        
FDE Capable: Not Capable
FDE Enable: Disable
Secured: Unsecured
Locked: Unlocked
Needs EKM Attention: No
Foreign State: None 
Device Speed: 12.0Gb/s 
Link Speed: 12.0Gb/s 
Media Type: Hard Disk Device
Drive Temperature :31C (87.80 F)
PI Eligibility:  Yes 
Number of bytes of user data in LBA: 512 
Drive is formatted for PI information:  Yes 
PI: PI with type 2
Port-0 :
Port status: Active
Port's Linkspeed: 12.0Gb/s 
Port-1 :
Port status: Active
Port's Linkspeed: 12.0Gb/s 
Drive has flagged a S.M.A.R.T alert : No

Virtual Drive: 5 (Target Id: 5)
Name                :
RAID Level          : Primary-0, Secondary-0, RAID Level Qualifier-0
Size                : 558.375 GB
Sector Size         : 512
Is VD emulated      : No
Parity Size         : 0
State               : Optimal
Strip Size          : 64 KB
Number Of Drives    : 1
Span Depth          : 1
Default Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU
Current Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU
Default Access Policy: Read/Write
Current Access Policy: Read/Write
Disk Cache Policy   : Disk's Default
Encryption Type     : None
Default Power Savings Policy: Controller Defined
Current Power Savings Policy: None
Can spin up in 1 minute: Yes
LD has drives that support T10 power conditions: Yes
LD's IO profile supports MAX power savings with cached writes: No
Bad Blocks Exist: No
PI type: No PI

Is VD Cached: No
Number of Spans: 1
Span: 0 - Number of PDs: 1

PD: 0 Information
Enclosure Device ID: 32
Slot Number: 6
Drive's position: DiskGroup: 5, Span: 0, Arm: 0
Enclosure position: 1
Device Id: 6
WWN: 50000396B81099DC
Sequence Number: 2
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SAS

Raw Size: 558.911 GB [0x45dd2fb0 Sectors]
Non Coerced Size: 558.411 GB [0x45cd2fb0 Sectors]
Coerced Size: 558.375 GB [0x45cc0000 Sectors]
Sector Size:  512
Logical Sector Size:  512
Physical Sector Size:  512
Firmware state: Online, Spun Up
Device Firmware Level: DK04
Shield Counter: 0
Successful diagnostics completion on :  N/A
SAS Address(0): 0x50000396b81099de
SAS Address(1): 0x0
Connected Port Number: 0(path0) 
Inquiry Data: TOSHIBA AL13SXB60EN     DK04Z570A0RAFHRC        
FDE Capable: Not Capable
FDE Enable: Disable
Secured: Unsecured
Locked: Unlocked
Needs EKM Attention: No
Foreign State: None 
Device Speed: 12.0Gb/s 
Link Speed: 12.0Gb/s 
Media Type: Hard Disk Device
Drive Temperature :31C (87.80 F)
PI Eligibility:  Yes 
Number of bytes of user data in LBA: 512 
Drive is formatted for PI information:  Yes 
PI: PI with type 2
Port-0 :
Port status: Active
Port's Linkspeed: 12.0Gb/s 
Port-1 :
Port status: Active
Port's Linkspeed: 12.0Gb/s 
Drive has flagged a S.M.A.R.T alert : No

Virtual Drive: 6 (Target Id: 6)
Name                :
RAID Level          : Primary-0, Secondary-0, RAID Level Qualifier-0
Size                : 558.375 GB
Sector Size         : 512
Is VD emulated      : No
Parity Size         : 0
State               : Optimal
Strip Size          : 64 KB
Number Of Drives    : 1
Span Depth          : 1
Default Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU
Current Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU
Default Access Policy: Read/Write
Current Access Policy: Read/Write
Disk Cache Policy   : Disk's Default
Encryption Type     : None
Default Power Savings Policy: Controller Defined
Current Power Savings Policy: None
Can spin up in 1 minute: Yes
LD has drives that support T10 power conditions: Yes
LD's IO profile supports MAX power savings with cached writes: No
Bad Blocks Exist: Yes
PI type: No PI

Is VD Cached: No
Number of Spans: 1
Span: 0 - Number of PDs: 1

PD: 0 Information
Enclosure Device ID: 32
Slot Number: 7
Drive's position: DiskGroup: 6, Span: 0, Arm: 0
Enclosure position: 1
Device Id: 7
WWN: 50000396B8109BBC
Sequence Number: 2
Media Error Count: 1
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SAS

Raw Size: 558.911 GB [0x45dd2fb0 Sectors]
Non Coerced Size: 558.411 GB [0x45cd2fb0 Sectors]
Coerced Size: 558.375 GB [0x45cc0000 Sectors]
Sector Size:  512
Logical Sector Size:  512
Physical Sector Size:  512
Firmware state: Online, Spun Up
Device Firmware Level: DK04
Shield Counter: 0
Successful diagnostics completion on :  N/A
SAS Address(0): 0x50000396b8109bbe
SAS Address(1): 0x0
Connected Port Number: 0(path0) 
Inquiry Data: TOSHIBA AL13SXB60EN     DK04Z570A0STFHRC        
FDE Capable: Not Capable
FDE Enable: Disable
Secured: Unsecured
Locked: Unlocked
Needs EKM Attention: No
Foreign State: None 
Device Speed: 12.0Gb/s 
Link Speed: 12.0Gb/s 
Media Type: Hard Disk Device
Drive Temperature :34C (93.20 F)
PI Eligibility:  Yes 
Number of bytes of user data in LBA: 512 
Drive is formatted for PI information:  Yes 
PI: PI with type 2
Port-0 :
Port status: Active
Port's Linkspeed: 12.0Gb/s 
Port-1 :
Port status: Active
Port's Linkspeed: 12.0Gb/s 
Drive has flagged a S.M.A.R.T alert : No

Virtual Drive: 7 (Target Id: 7)
Name                :
RAID Level          : Primary-0, Secondary-0, RAID Level Qualifier-0
Size                : 558.375 GB
Sector Size         : 512
Is VD emulated      : No
Parity Size         : 0
State               : Optimal
Strip Size          : 64 KB
Number Of Drives    : 1
Span Depth          : 1
Default Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU
Current Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU
Default Access Policy: Read/Write
Current Access Policy: Read/Write
Disk Cache Policy   : Disk's Default
Encryption Type     : None
Default Power Savings Policy: Controller Defined
Current Power Savings Policy: None
Can spin up in 1 minute: Yes
LD has drives that support T10 power conditions: Yes
LD's IO profile supports MAX power savings with cached writes: No
Bad Blocks Exist: No
PI type: No PI

Is VD Cached: No
Number of Spans: 1
Span: 0 - Number of PDs: 1

PD: 0 Information
Enclosure Device ID: 32
Slot Number: 8
Drive's position: DiskGroup: 7, Span: 0, Arm: 0
Enclosure position: 1
Device Id: 8
WWN: 50000396B81B83D0
Sequence Number: 2
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SAS

Raw Size: 558.911 GB [0x45dd2fb0 Sectors]
Non Coerced Size: 558.411 GB [0x45cd2fb0 Sectors]
Coerced Size: 558.375 GB [0x45cc0000 Sectors]
Sector Size:  512
Logical Sector Size:  512
Physical Sector Size:  512
Firmware state: Online, Spun Up
Device Firmware Level: DK04
Shield Counter: 0
Successful diagnostics completion on :  N/A
SAS Address(0): 0x50000396b81b83d2
SAS Address(1): 0x0
Connected Port Number: 0(path0) 
Inquiry Data: TOSHIBA AL13SXB60EN     DK04Z5C0A04VFHRC        
FDE Capable: Not Capable
FDE Enable: Disable
Secured: Unsecured
Locked: Unlocked
Needs EKM Attention: No
Foreign State: None 
Device Speed: 12.0Gb/s 
Link Speed: 12.0Gb/s 
Media Type: Hard Disk Device
Drive Temperature :36C (96.80 F)
PI Eligibility:  Yes 
Number of bytes of user data in LBA: 512 
Drive is formatted for PI information:  Yes 
PI: PI with type 2
Port-0 :
Port status: Active
Port's Linkspeed: 12.0Gb/s 
Port-1 :
Port status: Active
Port's Linkspeed: 12.0Gb/s 
Drive has flagged a S.M.A.R.T alert : No

Virtual Drive: 8 (Target Id: 8)
Name                :
RAID Level          : Primary-0, Secondary-0, RAID Level Qualifier-0
Size                : 558.375 GB
Sector Size         : 512
Is VD emulated      : No
Parity Size         : 0
State               : Optimal
Strip Size          : 64 KB
Number Of Drives    : 1
Span Depth          : 1
Default Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU
Current Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU
Default Access Policy: Read/Write
Current Access Policy: Read/Write
Disk Cache Policy   : Disk's Default
Encryption Type     : None
Default Power Savings Policy: Controller Defined
Current Power Savings Policy: None
Can spin up in 1 minute: Yes
LD has drives that support T10 power conditions: Yes
LD's IO profile supports MAX power savings with cached writes: No
Bad Blocks Exist: No
PI type: No PI

Is VD Cached: No
Number of Spans: 1
Span: 0 - Number of PDs: 1

PD: 0 Information
Enclosure Device ID: 32
Slot Number: 9
Drive's position: DiskGroup: 8, Span: 0, Arm: 0
Enclosure position: 1
Device Id: 9
WWN: 50000396B81B83E4
Sequence Number: 2
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SAS

Raw Size: 558.911 GB [0x45dd2fb0 Sectors]
Non Coerced Size: 558.411 GB [0x45cd2fb0 Sectors]
Coerced Size: 558.375 GB [0x45cc0000 Sectors]
Sector Size:  512
Logical Sector Size:  512
Physical Sector Size:  512
Firmware state: Online, Spun Up
Device Firmware Level: DK04
Shield Counter: 0
Successful diagnostics completion on :  N/A
SAS Address(0): 0x50000396b81b83e6
SAS Address(1): 0x0
Connected Port Number: 0(path0) 
Inquiry Data: TOSHIBA AL13SXB60EN     DK04Z5C0A04XFHRC        
FDE Capable: Not Capable
FDE Enable: Disable
Secured: Unsecured
Locked: Unlocked
Needs EKM Attention: No
Foreign State: None 
Device Speed: 12.0Gb/s 
Link Speed: 12.0Gb/s 
Media Type: Hard Disk Device
Drive Temperature :32C (89.60 F)
PI Eligibility:  Yes 
Number of bytes of user data in LBA: 512 
Drive is formatted for PI information:  Yes 
PI: PI with type 2
Port-0 :
Port status: Active
Port's Linkspeed: 12.0Gb/s 
Port-1 :
Port status: Active
Port's Linkspeed: 12.0Gb/s 
Drive has flagged a S.M.A.R.T alert : No

Virtual Drive: 9 (Target Id: 9)
Name                :
RAID Level          : Primary-0, Secondary-0, RAID Level Qualifier-0
Size                : 558.375 GB
Sector Size         : 512
Is VD emulated      : No
Parity Size         : 0
State               : Optimal
Strip Size          : 64 KB
Number Of Drives    : 1
Span Depth          : 1
Default Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU
Current Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU
Default Access Policy: Read/Write
Current Access Policy: Read/Write
Disk Cache Policy   : Disk's Default
Encryption Type     : None
Default Power Savings Policy: Controller Defined
Current Power Savings Policy: None
Can spin up in 1 minute: Yes
LD has drives that support T10 power conditions: Yes
LD's IO profile supports MAX power savings with cached writes: No
Bad Blocks Exist: No
PI type: No PI

Is VD Cached: No
Number of Spans: 1
Span: 0 - Number of PDs: 1

PD: 0 Information
Enclosure Device ID: 32
Slot Number: 10
Drive's position: DiskGroup: 9, Span: 0, Arm: 0
Enclosure position: 1
Device Id: 10
WWN: 50000396B82386E8
Sequence Number: 2
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SAS

Raw Size: 558.911 GB [0x45dd2fb0 Sectors]
Non Coerced Size: 558.411 GB [0x45cd2fb0 Sectors]
Coerced Size: 558.375 GB [0x45cc0000 Sectors]
Sector Size:  512
Logical Sector Size:  512
Physical Sector Size:  512
Firmware state: Online, Spun Up
Device Firmware Level: DK04
Shield Counter: 0
Successful diagnostics completion on :  N/A
SAS Address(0): 0x50000396b82386ea
SAS Address(1): 0x0
Connected Port Number: 0(path0) 
Inquiry Data: TOSHIBA AL13SXB60EN     DK04Z5E0A0FFFHRC        
FDE Capable: Not Capable
FDE Enable: Disable
Secured: Unsecured
Locked: Unlocked
Needs EKM Attention: No
Foreign State: None 
Device Speed: 12.0Gb/s 
Link Speed: 12.0Gb/s 
Media Type: Hard Disk Device
Drive Temperature :31C (87.80 F)
PI Eligibility:  Yes 
Number of bytes of user data in LBA: 512 
Drive is formatted for PI information:  Yes 
PI: PI with type 2
Port-0 :
Port status: Active
Port's Linkspeed: 12.0Gb/s 
Port-1 :
Port status: Active
Port's Linkspeed: 12.0Gb/s 
Drive has flagged a S.M.A.R.T alert : No

Virtual Drive: 10 (Target Id: 10)
Name                :
RAID Level          : Primary-0, Secondary-0, RAID Level Qualifier-0
Size                : 558.375 GB
Sector Size         : 512
Is VD emulated      : No
Parity Size         : 0
State               : Optimal
Strip Size          : 64 KB
Number Of Drives    : 1
Span Depth          : 1
Default Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU
Current Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU
Default Access Policy: Read/Write
Current Access Policy: Read/Write
Disk Cache Policy   : Disk's Default
Encryption Type     : None
Default Power Savings Policy: Controller Defined
Current Power Savings Policy: None
Can spin up in 1 minute: Yes
LD has drives that support T10 power conditions: Yes
LD's IO profile supports MAX power savings with cached writes: No
Bad Blocks Exist: No
PI type: No PI

Is VD Cached: No
Number of Spans: 1
Span: 0 - Number of PDs: 1

PD: 0 Information
Enclosure Device ID: 32
Slot Number: 11
Drive's position: DiskGroup: 10, Span: 0, Arm: 0
Enclosure position: 1
Device Id: 11
WWN: 50000396B81B83E0
Sequence Number: 2
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SAS

Raw Size: 558.911 GB [0x45dd2fb0 Sectors]
Non Coerced Size: 558.411 GB [0x45cd2fb0 Sectors]
Coerced Size: 558.375 GB [0x45cc0000 Sectors]
Sector Size:  512
Logical Sector Size:  512
Physical Sector Size:  512
Firmware state: Online, Spun Up
Device Firmware Level: DK04
Shield Counter: 0
Successful diagnostics completion on :  N/A
SAS Address(0): 0x50000396b81b83e2
SAS Address(1): 0x0
Connected Port Number: 0(path0) 
Inquiry Data: TOSHIBA AL13SXB60EN     DK04Z5C0A04WFHRC        
FDE Capable: Not Capable
FDE Enable: Disable
Secured: Unsecured
Locked: Unlocked
Needs EKM Attention: No
Foreign State: None 
Device Speed: 12.0Gb/s 
Link Speed: 12.0Gb/s 
Media Type: Hard Disk Device
Drive Temperature :31C (87.80 F)
PI Eligibility:  Yes 
Number of bytes of user data in LBA: 512 
Drive is formatted for PI information:  Yes 
PI: PI with type 2
Port-0 :
Port status: Active
Port's Linkspeed: 12.0Gb/s 
Port-1 :
Port status: Active
Port's Linkspeed: 12.0Gb/s 
Drive has flagged a S.M.A.R.T alert : No

Virtual Drive: 11 (Target Id: 11)
Name                :
RAID Level          : Primary-0, Secondary-0, RAID Level Qualifier-0
Size                : 558.375 GB
Sector Size         : 512
Is VD emulated      : No
Parity Size         : 0
State               : Optimal
Strip Size          : 64 KB
Number Of Drives    : 1
Span Depth          : 1
Default Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU
Current Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU
Default Access Policy: Read/Write
Current Access Policy: Read/Write
Disk Cache Policy   : Disk's Default
Encryption Type     : None
Default Power Savings Policy: Controller Defined
Current Power Savings Policy: None
Can spin up in 1 minute: Yes
LD has drives that support T10 power conditions: Yes
LD's IO profile supports MAX power savings with cached writes: No
Bad Blocks Exist: No
PI type: No PI

Is VD Cached: No
Number of Spans: 1
Span: 0 - Number of PDs: 1

PD: 0 Information
Enclosure Device ID: 32
Slot Number: 12
Drive's position: DiskGroup: 11, Span: 0, Arm: 0
Enclosure position: 1
Device Id: 12
WWN: 50000396B8205F4C
Sequence Number: 2
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SAS

Raw Size: 558.911 GB [0x45dd2fb0 Sectors]
Non Coerced Size: 558.411 GB [0x45cd2fb0 Sectors]
Coerced Size: 558.375 GB [0x45cc0000 Sectors]
Sector Size:  512
Logical Sector Size:  512
Physical Sector Size:  512
Firmware state: Online, Spun Up
Device Firmware Level: DK04
Shield Counter: 0
Successful diagnostics completion on :  N/A
SAS Address(0): 0x50000396b8205f4e
SAS Address(1): 0x0
Connected Port Number: 0(path0) 
Inquiry Data: TOSHIBA AL13SXB60EN     DK04Z5C0A0E7FHRC        
FDE Capable: Not Capable
FDE Enable: Disable
Secured: Unsecured
Locked: Unlocked
Needs EKM Attention: No
Foreign State: None 
Device Speed: 12.0Gb/s 
Link Speed: 12.0Gb/s 
Media Type: Hard Disk Device
Drive Temperature :30C (86.00 F)
PI Eligibility:  Yes 
Number of bytes of user data in LBA: 512 
Drive is formatted for PI information:  Yes 
PI: PI with type 2
Port-0 :
Port status: Active
Port's Linkspeed: 12.0Gb/s 
Port-1 :
Port status: Active
Port's Linkspeed: 12.0Gb/s 
Drive has flagged a S.M.A.R.T alert : No

Virtual Drive: 12 (Target Id: 12)
Name                :
RAID Level          : Primary-0, Secondary-0, RAID Level Qualifier-0
Size                : 446.625 GB
Sector Size         : 512
Is VD emulated      : Yes
Parity Size         : 0
State               : Optimal
Strip Size          : 64 KB
Number Of Drives    : 1
Span Depth          : 1
Default Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU
Current Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU
Default Access Policy: Read/Write
Current Access Policy: Read/Write
Disk Cache Policy   : Disk's Default
Encryption Type     : None
Default Power Savings Policy: Controller Defined
Current Power Savings Policy: None
Can spin up in 1 minute: No
LD has drives that support T10 power conditions: No
LD's IO profile supports MAX power savings with cached writes: No
Bad Blocks Exist: No
PI type: No PI

Is VD Cached: No
Number of Spans: 1
Span: 0 - Number of PDs: 1

PD: 0 Information
Enclosure Device ID: 32
Slot Number: 21
Drive's position: DiskGroup: 12, Span: 0, Arm: 0
Enclosure position: 1
Device Id: 21
WWN: 55cd2e404c18ebe1
Sequence Number: 2
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SATA

Raw Size: 447.130 GB [0x37e436b0 Sectors]
Non Coerced Size: 446.630 GB [0x37d436b0 Sectors]
Coerced Size: 446.625 GB [0x37d40000 Sectors]
Sector Size:  512
Logical Sector Size:  512
Physical Sector Size:  4096
Firmware state: Online, Spun Up
Device Firmware Level: 0140
Shield Counter: 0
Successful diagnostics completion on :  N/A
SAS Address(0): 0x500056b3dd23cbd5
Connected Port Number: 0(path0) 
Inquiry Data: BTHC6022021H480MGN  INTEL SSDSC2BX480G4                     G2010140
FDE Capable: Not Capable
FDE Enable: Disable
Secured: Unsecured
Locked: Unlocked
Needs EKM Attention: No
Foreign State: None 
Device Speed: 6.0Gb/s 
Link Speed: 6.0Gb/s 
Media Type: Solid State Device
Drive:  Not Certified
Drive Temperature :21C (69.80 F)
PI Eligibility:  No 
Drive is formatted for PI information:  No
PI: No PI
Drive's NCQ setting : N/A
Port-0 :
Port status: Active
Port's Linkspeed: 6.0Gb/s 
Drive has flagged a S.M.A.R.T alert : No

Virtual Drive: 13 (Target Id: 13)
Name                :
RAID Level          : Primary-0, Secondary-0, RAID Level Qualifier-0
Size                : 446.625 GB
Sector Size         : 512
Is VD emulated      : Yes
Parity Size         : 0
State               : Optimal
Strip Size          : 64 KB
Number Of Drives    : 1
Span Depth          : 1
Default Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU
Current Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU
Default Access Policy: Read/Write
Current Access Policy: Read/Write
Disk Cache Policy   : Disk's Default
Encryption Type     : None
Default Power Savings Policy: Controller Defined
Current Power Savings Policy: None
Can spin up in 1 minute: No
LD has drives that support T10 power conditions: No
LD's IO profile supports MAX power savings with cached writes: No
Bad Blocks Exist: No
PI type: No PI

Is VD Cached: No
Number of Spans: 1
Span: 0 - Number of PDs: 1

PD: 0 Information
Enclosure Device ID: 32
Slot Number: 22
Drive's position: DiskGroup: 13, Span: 0, Arm: 0
Enclosure position: 1
Device Id: 22
WWN: 55cd2e404c1f3b86
Sequence Number: 2
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SATA

Raw Size: 447.130 GB [0x37e436b0 Sectors]
Non Coerced Size: 446.630 GB [0x37d436b0 Sectors]
Coerced Size: 446.625 GB [0x37d40000 Sectors]
Sector Size:  512
Logical Sector Size:  512
Physical Sector Size:  4096
Firmware state: Online, Spun Up
Device Firmware Level: 0140
Shield Counter: 0
Successful diagnostics completion on :  N/A
SAS Address(0): 0x500056b3dd23cbd6
Connected Port Number: 0(path0) 
Inquiry Data: BTHC613401Z5480MGN  INTEL SSDSC2BX480G4                     G2010140
FDE Capable: Not Capable
FDE Enable: Disable
Secured: Unsecured
Locked: Unlocked
Needs EKM Attention: No
Foreign State: None 
Device Speed: 6.0Gb/s 
Link Speed: 6.0Gb/s 
Media Type: Solid State Device
Drive:  Not Certified
Drive Temperature :21C (69.80 F)
PI Eligibility:  No 
Drive is formatted for PI information:  No
PI: No PI
Drive's NCQ setting : N/A
Port-0 :
Port status: Active
Port's Linkspeed: 6.0Gb/s 
Drive has flagged a S.M.A.R.T alert : No

Virtual Drive: 14 (Target Id: 14)
Name                :
RAID Level          : Primary-0, Secondary-0, RAID Level Qualifier-0
Size                : 446.625 GB
Sector Size         : 512
Is VD emulated      : Yes
Parity Size         : 0
State               : Optimal
Strip Size          : 64 KB
Number Of Drives    : 1
Span Depth          : 1
Default Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU
Current Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU
Default Access Policy: Read/Write
Current Access Policy: Read/Write
Disk Cache Policy   : Disk's Default
Encryption Type     : None
Default Power Savings Policy: Controller Defined
Current Power Savings Policy: None
Can spin up in 1 minute: No
LD has drives that support T10 power conditions: No
LD's IO profile supports MAX power savings with cached writes: No
Bad Blocks Exist: No
PI type: No PI

Is VD Cached: No
Number of Spans: 1
Span: 0 - Number of PDs: 1

PD: 0 Information
Enclosure Device ID: 32
Slot Number: 23
Drive's position: DiskGroup: 14, Span: 0, Arm: 0
Enclosure position: 1
Device Id: 23
WWN: 55cd2e404c18ec02
Sequence Number: 2
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SATA

Raw Size: 447.130 GB [0x37e436b0 Sectors]
Non Coerced Size: 446.630 GB [0x37d436b0 Sectors]
Coerced Size: 446.625 GB [0x37d40000 Sectors]
Sector Size:  512
Logical Sector Size:  512
Physical Sector Size:  4096
Firmware state: Online, Spun Up
Device Firmware Level: 0140
Shield Counter: 0
Successful diagnostics completion on :  N/A
SAS Address(0): 0x500056b3dd23cbd7
Connected Port Number: 0(path0) 
Inquiry Data: BTHC6022022G480MGN  INTEL SSDSC2BX480G4                     G2010140
FDE Capable: Not Capable
FDE Enable: Disable
Secured: Unsecured
Locked: Unlocked
Needs EKM Attention: No
Foreign State: None 
Device Speed: 6.0Gb/s 
Link Speed: 6.0Gb/s 
Media Type: Solid State Device
Drive:  Not Certified
Drive Temperature :21C (69.80 F)
PI Eligibility:  No 
Drive is formatted for PI information:  No
PI: No PI
Drive's NCQ setting : N/A
Port-0 :
Port status: Active
Port's Linkspeed: 6.0Gb/s 
Drive has flagged a S.M.A.R.T alert : No

Exit Code: 0x00

猜你喜欢