Industrial automation UHF RFID reader | sensor | read-write head CK-UR08-B01 and PLC online networking method

  Industrial Automation UHF RFID Reader|Sensor|Read/Write Head CK-UR08-B01 is an UHF card reader based on RS232, MODBUS RTU communication protocol, which can support multiple readers to work in a network at the same time Multiple CK-UR08-B01 devices are mounted on the bus, which can be networked and controlled with PLC, which is suitable for applications in the field of EMS manufacturing systems. The following introduces the online networking method of industrial automation UHF RFID reader|sensor|read-write head CK-UR08-B01 and PLC.

Before introducing the industrial automation UHF RFID reader | sensor | read-write head CK-UR08-B01 and PLC online networking method, we first understand the external electrical of CK-UR08-B01, so that we can quickly understand how to install And application.

Figure 4.1 External electrical diagram of CK-UR08-B01 card reader

1 Card reader cable connector--M12, A-coded, 5 PIN male

2 Power indicator/Update indicator

3 RFID status indicator

4 Shell ground terminal

Next we understand the industrial automation UHF RFID reader | sensor | the LED indicator of the reader CK-UR08-B01

The LED indicator related instructions are as follows:

Table 4.1 Indicator status description

Indicator light

colour

status

Instruction content

Power indicator/update indicator

Green light

Chang Liang

Connected to the power supply, the card reader is working

Flashing

Firmware update

RFID status indicator

Green light

Chang Liang

Valid RFID tag detected

​​​​​​​Again, let's learn the wiring instructions of the industrial automation UHF RFID reader | sensor | read-write head CK-UR08-B01

The CK-UR08-B01 wiring terminal is defined as follows:

Figure 4.2 CK-UR08-B01 wiring terminal definition

CK-UR08-B01:

Table 4.2 CK-UR08-B01 terminal description

Connection Terminal No.

interface

Description

1

VCC

Card reader power supply 24V

2

TXD

RS232 communication port to send TX pin

3

GND

Reader 0V

4

RXD

RS232 communication port receiving RX pin

5

SG

RS232 signal ground

​​​​​​​Finally, let's take a look again. Let's learn the networking method of industrial automation UHF RFID reader|sensor|read-write head CK-UR08-B01 and PLC:

When CK-UR08-B01 is working in stand - alone mode, the wiring is as follows:

Figure 4.3 CK-UR08-B01 stand-alone communication