可以使用sg_vpd命令查看硬盘转速,sg_vpd命令是sg3_utils其中一个工具. 下载地址:http://sg.danny.cz/sg/sg3_utils.html VPD:Vital Product Data
# sg_vpd /dev/sg8 –page=0×89
ATA information VPD page:
SAT Vendor identification: LSI
SAT Product identification: LSI SATL
SAT Product revision level: 0008
ATA command IDENTIFY DEVICE response summary:
model: ST31000340NS
serial number: 9QJ4VPL1
firmware revision: SN06
# sg_vpd /dev/sg8 –page=0xb1
Block device characteristics VPD page (SBC):
Nominal rotation rate: 7200 rpm
Nominal form factor not reported
# sg_vpd /dev/sg8 -e
Standard VPD pages:
ai 0×89 ATA information (SAT)
aod 0×82 ASCII implemented operating definition (obsolete)
adsn 0xb3 Automation device serial number (SSC)
bl 0xb0 Block limits (SBC)
bdc 0xb1 Block device characteristics (SBC)
cfa 0x8c CFA profile information
dc 0x8b Device constituents
di 0×83 Device identification
di_asis 0×83 Like ‘di’ but designators ordered as found
di_lu 0×83 Device identification, lu only
di_port 0×83 Device identification, target port only
di_target 0×83 Device identification, target device only
dtde 0xb4 Data transfer device element address (SSC)
ei 0×86 Extended inquiry data
iod 0×81 Implemented operating definition (obsolete)
lbpv 0xb2 Logical block provisioning (SBC)
mas 0xb1 Manufacturer assigned serial number (SSC)
masa 0xb1 Manufacturer assigned serial number (ADC)
mna 0×85 Management network addresses
mpp 0×87 Mode page policy
oi 0xb0 OSD information
po 0x8a Power condition
pslu 0×90 Protocol-specific logical unit information
pspo 0×91 Protocol-specific port information
ref 0xb3 Referrals (SBC)
sad 0xb0 Sequential access device capabilities (SSC)
sii 0×84 Software interface identification
sn 0×80 Unit serial number
sp 0×88 SCSI ports
st 0xb1 Security token (OSD)
sv 0×00 Supported VPD pages
tas 0xb2 TapeAlert supported flags (SSC)
Vendor specific VPD pages:
datc 0xc1,0 Date code (Seagate)
devb 0xc3,0 Device behavior (Seagate)
edid 0xc8,0 Extended device identification (RDAC)
feat 0xc3,1 Feature Parameters (RDAC)
firm 0xc0,0 Firmware numbers (Seagate)
jump 0xc2,0 Jump setting (Seagate)
sub 0xc4,0 Subsystem identifier (RDAC)
sver 0xc2,1 Software version (RDAC)
upr 0xc0,1 Unit path report (EMC)
vac 0xc9,0 Volume access control (RDAC)
转载于:https://my.oschina.net/766/blog/211338