Common installation issues of UG NX mechanical design software

We won’t mention the UG software version here. Most partners should use hook activation software, and they will definitely encounter more or less installation problems. Today I’ve summarized it for you. Those who need it can pick it up themselves.

If you have any other questions, we can discuss them together. I also hope that friends who see it will pay more attention and support.
Insert image description here

Necessary points for installing UGNX:

1. Download the complete installation package

2. Turn off the anti-virus software and firewall before decompression (programs may be accidentally deleted during the decompression process)

3. The computer name cannot have Chinese characters (very important)

4. The installation path and installation directory should not contain Chinese characters (very important)

5. After installing and running UG, it cannot be opened and there is no prompt. The simple solution is to change the computer system, or find the UG upgrade package.

After UG is installed, it opens in English:

Insert image description here

Find My Computer on the computer desktop, right-click, then select Properties, click Advanced System Settings, and select Environment Variables.

1. Check whether there is lang=chs in the user variables. If not, please create a new user variable.

2. Then look at the system variables to see if the variable value of UGII_LANG is simple_chinese. If you do not click edit, it is easy to enter the above letters incorrectly. For example, incorrectly entering l as 1 or I will have no effect.

After modifying the system variables, you must restart the computer to take effect.

Insert image description here

If the software is still in English when you restart it after modification, then you unchecked the default language name when installing the NX software to prevent the software from installing the language pack. This is extremely unlikely.

Tip Warning 1946 Unable to set shortcut...:

Insert image description here

If you encounter the above problems, it means that the software has been successfully installed. However, if you do not have system permissions when creating a shortcut, a warning will be prompted. We can modify the system permissions and reinstall the main program to solve the problem.

You can also refer to the following path to find the shortcut and send it to the desktop

D:\Program Files\Siemens\NX 12.0\NXBIN\ugraf.exe

Tip NX initialization error:

NX Initialization Error

Insert image description here

This situation is mostly caused by unsuccessful installation of UG software many times, and then when uninstalling the software, it was not uninstalled cleanly.

Solution: You need to uninstall the UG software in the system control panel, uninstall the program, then find the installation directory and delete the directory. You can use a security guard or the like to clean the registry. Restart your computer and reinstall.

ugraf.exe System Error: This program cannot be started

Insert image description here

This type of problem is caused by system reasons. Many people have a streamlined version of the system installed on their computers. The streamlined version of the system deletes many files that are not commonly used. UG just needs this file and all system errors will appear. Just change the system. Or if you don’t mind the trouble, you can look for the missing file as prompted.

After installation, open the prompt: linitialization-COLLAPSE

Line 1344 of o…

Insert image description here

If this problem occurs, you can create a new folder on the C drive and rename the folder to TEMP.

Then right-click My Computer on the desktop, click Properties, then click Advanced, System Settings, Environment Variables, New Environment Variable,

variable name:

UGII_TMP_DIR

variable:

C:\TEMP

Insert image description here

NX initialization error:

NX License Error: The license server is down or not responding. Please check whether SPLM_LICENSE_SERVER is set correctly. [-96]
Insert image description here

This situation is usually caused by not exiting the anti-virus and turning off the firewall when installing or replacing the P solution program. Also, please note that the computer name cannot have Chinese characters, and the installation path must not have Chinese characters. If there are Chinese characters, the above problems will also occur. If the computer has a Chinese name or the installation path The path folder has Chinese characters. Uninstall the software, change the name, and reinstall it.

NX initialization error:

License error, server not connected. [-10004]
Insert image description here

Initialization Error:License Error,server not connected.[-10004]
Insert image description here

These two pictures are a problem, because there is a prompt in English and a Chinese prompt for the issue of environment variables.

If this problem occurs, first check whether your P solution file has been replaced, and whether the anti-virus and firewall have been turned off.

In addition, when installing the NX12.0 main program, please pay attention. During the installation process, remember to change the port to 27800. If you have completed the installation and the above error is prompted, change the SPLM_LICENSE_SERVER variable value in the system environment variable from the original 28000 to 27800 is enough. Note that under normal circumstances, the computer name behind @ should not be touched. (Please see clearly, some users see it as UGS_LICENSE_SERVER, which is wrong.)

Standard format: 27800@your computer name

Insert image description here

NX Initialization Error:Bad splash screen filename.

Insert image description here

When this kind of problem occurs, please pay attention to whether your installation path has a Chinese name, or if you have installed and uninstalled it before without cleaning the registry. If the software path has Chinese characters, you need to uninstall the software, change it, clean the registry, and reinstall.

Siemens NX8.5 installer information:

The CAB file "NXHUMAN.cab" required for this installation is damaged and cannot be used. This may indicate a network error, an error reading the CD-ROM, or a bug in this package.

Insert image description here

This situation is mainly caused by the incomplete installation package. The installation package was decompressed before downloading. The anti-virus was not exited before decompression after the installation package was downloaded or the files were accidentally deleted during decompression by the firewall. Problems with the decompression software can also cause this problem. You can change it. Try using software like Haoyao to decompress it.

NX Initialization Error:

UGII_TMP_DIR is set to a directory with invalid (non-ASCII) characters.

Insert image description here

This prompt appears. Check whether the computer windows system account uses a Chinese name.

Solution: You can create a new folder on the C drive and rename TEMP. If there is such a folder, there is no need to create it. Then go to the desktop and find "My Computer", right-click properties, Advanced System Settings-Advanced-Environment Variables-New environment variables.

variable name:

UGII_TMP_DIR

variable:

C:\TEMP

Insert image description here

NX initialization error:

License error, the version of the server_id feature is incompatible with the product version of the application. [-10097]

Insert image description here

When this prompt appears, check whether the old version of the UG license is installed and running on the computer and restart the computer.

Solution: Uninstall Siemens PLM License Server (NX licensing service program) in the control panel

Insert image description here

NX Initialization Error:

NX configuration Error:Environment variable UGII_UTF8_MODE is not supported.

Insert image description here

This prompt is that when you installed the UG8.0 software before, you added an environment variable UGII_UTF8_MODE tested internally by Siemens to support Chinese variables. This is a variable that cannot be supported in UG8.5, so an error message will appear.

Solution: Delete the UGII_UTF8_MODE=1 environment variable in the system environment variables.

Insert image description here

Be careful to delete this environment variable. If UG8.0 is still installed on your computer, you may not be able to open previous image files normally.

Initialization-COLLAPSE:

Line 1156 of o:\ugnx85…The evvironment variable UGII_TMP_DIR set to C:\Users…\AppData\local\Temp causes an error.

Insert image description here

When this problem occurs, check whether your system name is Chinese.

The solution is to create a new folder in the C drive (system drive) and name it: TEMP. If this folder already exists, there is no need to create it.

Then add an environment variable to the computer system environment variables.

variable name:

UGII_TMP_DIR

variable:

C:\TEMP

Remember to restart your computer after creating new system variables. (Modify the picture below)

Insert image description here

Initialization error:

NX License Error:Thedesired vendor daemon is down.[-97]

Insert image description here

This is a common NX license error, code-named -97, and its meaning is to tell you: Your NX license service has not started.

There are many reasons why the NX licensing service cannot start, so this prompt does not tell you much information about what went wrong.

1. After the NX licensing service is installed, you must restart the computer first. After restarting, the NX licensing service can start automatically.

2. The computer name in the LIC license file is not modified correctly or is in the wrong format.

3. The XX file was not replaced and overwritten correctly.

4. NX licensing service conflict, you have installed multiple versions of licenses, NX2NX4, NX6NX12, NX1847, if you are There are two license services installed. Please uninstall them in the control panel. If they are not available in the control panel, you can manually delete the duplicate licenses

5. Your computer’s firewall and anti-virus software will also accidentally delete such programs. Try to exit the anti-virus and close the firewall during installation.

Siemens NX 10.0 installer information:

Data errors (cyclic redundancy check).

Insert image description here

Right-click on the hard drive letter where you installed the software - Properties - Tools - Start Checking - Defragment immediately, and then restart the computer.

Insert image description here

Siemens PLM Documentation Server:

The service Siemens PLM Documentation Server failed to start. Please confirm that you have sufficient permissions to start system services.

Insert image description here

When this prompt appears, we can skip the license installation and install the main program directly. After installing the main program and installing the license, there will be no such prompt.

Unable to schedule file replacement on restart, please verify that you have write permissions to the file mfc100.dll:
Insert image description here

If you encounter this prompt, please exit the anti-virus software, Security Guard, turn off the firewall, and then install.

Siemens PLM License Server:

Invalid server name, the server specified in the license file is ***, but the actual host name is ***. Do you want to continue the installation anyway?

Insert image description here

What needs to be clearly understood about this problem is that the two computer names on the warning prompt are exactly the same, instead of prompting different computer names, which is another solution.

reason:

Blocked by firewalls, complete software, etc. In most cases it's the system firewall.

Solution:

Turn off the firewall or complete the software and try the installation again.

Windows error when loading java VM: 2

Insert image description here

This problem is usually a JAVA problem. Check the control panel to see if there are other versions of JAVA in the program uninstall. If so, you can try to uninstall it first.

Then you can check whether you have set the JAVA environment variable in the environment variables. If so, delete it. After the above operations are completed, restart the computer and try again.

1. Check the system control panel - Programs, and uninstall all JAVA first, because multiple versions of JAVA can be installed at the same time, and similar problems will occur if the versions are disordered.

2. Install the JAVA installation package that matches NX10.0.

Prompt installation error:

The program's digital signature is invalid and the program will exit now.

Solution: The reason is because the computer is not connected to the Internet. As long as the Internet cable is plugged in and the network can be accessed, the installation can be normal.

Siemens NX installer:

An overlapped I/O operation is in progress.

Insert image description here

Solution: Click Folder Options, explicitly hide the file, find the following file: C:\ProgramData\Microsoft\Crypto\RSA\S-1-5-18 and rename it to: C:\ProgramData\Microsoft\Crypto\RSA\ S-1-5-18_BAK, or delete S-1-5-18 directly.

After the installation of NX1847 is completed, when opening the software, it prompts:

Terminating due to unable to find valid directory to create syslog file.

Insert image description here

solution:

First create a new folder on the C drive (system drive) and name it: TEMP. If this folder already exists, there is no need to create it.

Then add an environment variable to the computer system environment variables.

variable name:

UGII_TMP_DIR

variable:

C:\TEMP

Restart the computer.

Guess you like

Origin blog.csdn.net/u014740628/article/details/134132071