ABB robot 20032 revolution counter is not updated fault alarm processing method

ABB robot 20032 revolution counter is not updated fault alarm processing method

0.1
ABB's robots are equipped with batteries that need to be replaced regularly (normally once a year). If they are not replaced for a long time and the battery is too low, an alarm will appear that the revolution counter has not been updated, and the position of each axis encoder will be lost. , after replacing the new battery, the revolution counter needs to be updated.

Specific steps are as follows:

1

  1. First manually move the 6 axes to the synchronous position, there will be a scale mark on each axis, just align it, as shown in the figure below
    2
    3
  2. After the six axes are in place, click to enter the menu interface and select "Calibrate", as shown in the figure below,
    4
  3. Select the robot to calibrate