2022 Grade One Registered Architect Architectural Structure Examination Daily Practice and Answers

Question bank source: Youtibao public account

The daily practice and answers of the 2022 Grade 1 Registered Architect Architectural Structure Examination will be compiled by the Youtibao official account based on the latest Grade 1 Registered Architect Architectural Structure Examination syllabus and the previous years' Grade 1 Registered Architect Architectural Structure Examination Real Questions, including a The key question types and knowledge points of the Grade 1 Registered Architect Architectural Structure Examination often help candidates review and prepare for the Grade 1 Registered Architect Architectural Structure Exam and achieve good results.

 

 

1. For reinforced concrete rectangular bending columns, in order to reduce cracks, the most effective is ().

A. Encrypt the stirrup spacing

B. Improve the strength of steel bars

C. Choose large diameter steel bars

D. Increase the reinforcement ratio of the main reinforcement

2. Which of the following types of structures in reinforced concrete high-rise buildings has the highest maximum applicable height? ()

A. Frame structure

B. All floor-to-ceiling shear wall structures

C. Partially frame-supported shear wall structure

D. Tube-in-tube structure

3. The following types of buildings may not consider the seismic bearing capacity of natural foundations and foundations are ( ).

A. Single-story factory building with weak cohesive soil in the main bearing layer of the foundation

B. Chimneys with a height of not more than 100m at 9 degrees

C. Masonry houses

D. A chimney with a height of 150m at 7 degrees

4. The intersection of the transverse stiffening rib plate of the welded steel beam with the flange plate and the web plate should be chamfered for the purpose of ().

A. Prevent corner welding

B. Reserved welding vents

C. Avoid stress concentration in welds

D. It is convenient for welders to weld

5. Generally speaking, the components suitable for prestressed concrete are ( ).

Ⅰ. Axial tension member;

Ⅱ. Axial compression member;

Ⅲ. Bending member;

Ⅳ. Eccentric tension members

A.Ⅰ、Ⅱ、Ⅲ

B.Ⅱ、Ⅲ、Ⅳ

C.Ⅰ、Ⅲ、Ⅳ

D.Ⅰ、Ⅱ、Ⅳ

【Answer】

1 ~ 5: DDCCC

The above is the daily practice and answers of the first-level registered architect architectural structure examination. Xiaobian and Youtibao will continue to update the real-test simulation questions and answer analysis of the first-level registered architect architectural structure examination. miss. I also hope that all candidates can achieve good results in the first-level registered architect architectural structure examination.

 

 