IBM X System ServerGuide 8.41 installation boot disk server system

IBM X System ServerGuide 8.41

Supported operating systems:

# 32:

Microsoft Windows 2003/2003 R2 (Enterprise, Standard, Web and DataCenter UV)

Microsoft Small Business Server 2003/2003 R2 (Standard/Premium Edition)

Microsoft Windows 2008 (Enterprise, Standard, Web and DataCenter)

# 64:

Microsoft Windows 2003/2003 R2 (Enterprise, Standard, and DataCenter UV)

Microsoft Windows 2008

(Enterprise, Standard, DataCenter, Essential Business Server, Small Business Server and HPC Edition)

Microsoft Windows Server 2008 R2 (Enterprise, Standard, Web, DataCenter, and HPC Edition)

Support server series:

IBM BladeCenter LS20 (8850)

IBM BladeCenter LS21 (7971)

IBM BladeCenter LS22 (7901)

IBM BladeCenter LS41 (7972)

IBM BladeCenter LS42 (7902)

IBM BladeCenter HS12 (8014, 8028, 1916)

IBM BladeCenter HS20 (8843, 1883)

IBM BladeCenter HS21 (8853, 1885)

IBM BladeCenter HS21 XM (7995, 1915)

IBM BladeCenter HS22 (7870, 1936, 7809)

IBM BladeCenter HS22V (7871, 1949)

IBM BladeCenter HX5 (7872, 1909)

IBM BladeCenter S (8886)

IBM eServer xSeries 260 (8865)

IBM eServer xSeries 366 (8863)

IBM eServer xSeries 460 (8872)

IBM System x3100 (4348)

IBM System x3105 (4347)

IBM System x3200 (4362, 4363)

IBM System x3200 M2 (4367, 4368)

IBM System x3200 M3 (7327, 7328)

IBM System x3250 (4364, 4365, 4366)

IBM System x3250 M2 (4190, 4191, 4194)

IBM System x3250 M3 (4251, 4252, 4261)

IBM System x3350 (4192, 4193)

IBM System x3400 (7973, 7974, 7975, 7976)

IBM System x3400 M2 (7846, 7837)

IBM System x3400 M3 (7378, 7379)

IBM System x3455 (7984, 7986, 7940, 7941)

IBM System x3500 (7977)

IBM System x3500 M2 (7839)

IBM System x3500 M3 (7380)

IBM System x3550 (7978, 1913)

IBM System x3550 M2 (7946, 4198)

IBM System x3550 M3 (7944, 4254)

IBM System x3610 (7942) (RAID support requires BIOS level 1.01A or above)

IBM System x3620 M3 (7376)

IBM System x3630 M3 (7377)

IBM System x3650 (7979, 1914)

IBM System x3650 M2 (7947, 4199)

IBM System x3650 M3 (7945, 4255)

IBM System x3650 T (7980)

IBM System x3655 (7985, 7943)

IBM System x3690 X5 (7148, 7149)

IBM System x3755 (8877, 7163)

IBM System x3800 (8865, 8866)

IBM System x3850 (8864, 7365, 7362)

IBM System x3850 M2 (7141, 7144, 7233, 7234)

IBM System x3850 X5 (7145)

IBM System x3950 (7366, 8878, 7363, 8872)

IBM System x3950 M2 (7141, 7233, 7234)

IBM System x3950 X5 (7146)

IBM System iDataplex dx360 M2 (7321, 7323, 6830)

IBM System x iDataPlex dx360 M3 (6391)

 

download link:

# 32:

http://delivery04-bld.dhe.ibm.com/sar/CMA/XSA/013g9/0/ibm_utl_sguide_8.41_anyos_i386.iso

# 64:

http://delivery04-bld.dhe.ibm.com/sar/CMA/XSA/013gb/0/ibm_utl_sguide_8.41_anyos_x86-64.iso

 

 

Setup and configuration overview:

When you use the ServerGuide Setup and Installation CD, you do not need to install a floppy disk. You can use the CD to configure any supported IBM server model. The installer provides a list of tasks required to install the server model. On the server integrated SAS controller with a ServeRAID adapter or with RAID capabilities, you can create logical drives in the phase configuration of the array.

note:

1. Using the ServerGuide CD-ROM installation will erase partitions and data on the hard disk, choose another installation method if you want to keep the data as well as make a backup copy or,

2, ServerGuide CD does not contain operating system programs, prepare their own customers a genuine Windows operating system CD.

Here to guide through the ServerGuide CD-ROM install Microsoft Windows Server 2003 Enterprise version of the operating system as an example:

3. This machine does not require a single tape drive with a USB drive, boot and press F12, select the CD / DVD

1, start the server using ServerGuide CD, there will be a few minutes of the boot process, please wait.

Select the language of this guide plate (note: this time is ServerGuide boot language programming language, and to be installed operating system), the following screen appears, select the "English"

2, the keyboard layout selection screen, where selecting "United States", and then click the "NEXT":

3, Chinese users can choose to read Chinese Chinese Language option agreement,

License agreement screen appears, read the license agreement, click "I accept" to continue:

4. View the overview to learn about ServerGuide features, please view the instructions carefully before using, click "NEXT" to continue:

5, where you can select the operating system you want to install, select and click "NEXT":

6, after setting the correct date and time click "NEXT":

7, this time into the array configuration phase:

(1), if the array is not disposed over the server as shown below:

On the right half of the center line of the array card information will be displayed, and the current number of drives the array. In sufficient quantity to support an array of card and hard drive case in Select RAID Level array of options there will be some level you can configure optional. If you do not need to configure the array, you can select "Bypass RAID Configuration" option between the image above and click "NEXT" to continue.

――――――――――――――――――――――――――――――――――

Alternatively Array Level Description:

RAID Defaults: using default configuration array (a hard default configuration Volume, 2 hard disk drives default configuration over Raid1,3 default configuration Raid5)

RAID 0: use all available hard disk configuration a Raid0

RAID 1: Before using a two disk configuration Raid1

RAID 10: 4 before use a disk configuration Raid10

RAID 5: using all available hard disks arranged one Raid5

RAID 1 + RAID 1: 2 before use Raid1 a disk configuration, and then followed by the use of a two disk configuration Raid1

RAID 1 + RAID 5: Before using a two disk configuration Raid1, and then using the remaining disk configuration 1 Raid5

Add Hot Sopare: If checked, will default to a hard drive as a hot spare hard disk

―――――――――――――――――――――――――――――――――――――――

Will appear after (2), if configured arrays in the previous step, then move to the next page array status Status is Configuring (Configuring):

After the configuration status displays Completed, click "NEXT" to continue.

After the configuration status displays Completed:

(5) After configuration is complete click "NEXT" to continue, if not done any array operation, you'll go to step 8. If done array operation, then enters shown below:

Tip ServerGuide need to restart the server to initialize the array, click "NEXT" to restart, please wait ServerGuide during reboot, do not do anything.

8. As shown below into the partition and the file system type selected, do not pay attention when the partition is less than the capacity of 8G :( value at that time as the input capacity of the system partition, i.e., disk capacity C; the remaining disk space management system to not divided state occurs)

Note: ServerGuide will erase all data and logical partitions of one hard disk drive or an array of first default. If you select Clear All Disks, then cleared so the hard disk and the data on the array. If other important data on the hard disk, it would be best to back out.

9, Click "NEXT" to create a partition and format the implementation of the operation, it will be displayed after the completion of the following figure:

10, click "NEXT" to the next figure, shows some details of the server:

Information server configured to check for errors, and then click "NEXT":

11, the following configuration settings to start installation of windows:

Enter your user name in the following interface, the computer name and serial number, pay attention to "Product ID *" to enter

The serial number of the Windows operating system CD-ROM (Note: Required items marked with an asterisk);

12, select the server's network settings:

13, select Settings card, you can press the default type of card to be installed and can be changed until the operating system is installed:

14, select the number of license WIN2003 system:

15, into the operating system interface language and country settings,

In the item selected time zone "(GMT + 08: 00) Beijing, Chongqing, Hong Kong, Urumqi"

Select "Chinese (PRC)" item in the main language;

Select "Simplified Chinese" language entry in the second term, the other voice entries are canceled;

(Note: If you installed windows are Chinese Simplified, must be changed in accordance with the above options, there would be garbled after the system is installed);

16, in the following interface selection windows components you want to install, can be installed in the system after Bahrain, click "NEXT" to continue:

17, ServerGuide will be prompted to copy the windows drivers and related installation file, click "NEXT" to continue:

18, after the data copy is complete, the following message appears, click "NEXT" to continue:

19, ServerGuide CD will automatically pop up, prompting you to choose and need to be replaced at the start of the corresponding Windows operating system CD and click "NEXT" to continue:

20, insert the Windows CD, it will automatically search, after finding the disc interface will be shown in the following figure, if the disc does not match, you will be prompted to re-insert the disc.

21, after reading the Microsoft End User License Manual select "I agree" (Note: There are likely to see is garbled, since there is currently no ServerGuide CD-ROM that comes with Chinese font, but will not have the system installed garbled)

 22, began to copy the windows installation files:

23. The disc screen requires WINDOWS removed, and then click the "NEXT" confirm restart the server, then the server will go unattended installation, thus ServerGuide disc configuration process is complete. Several times during the restart, without intervention, please wait.

Guess you like

Origin www.cnblogs.com/jijm123/p/12129503.html