Huawei Device Configuration File Management

1, Huawei Device Configuration File Management

Management Huawei device configuration file has three basic concepts: the current configuration, the configuration file, the next startup configuration file.

  (1), the current configuration:

    Configuration information in the device memory is called the current configuration of the device, which is currently running configuration of the device, when the device is powered down or rebooted, all memory of the Central Plains and some information will be lost.

 (2), the configuration file:

    File contains the device configuration information present in the external memory device, the file name format is generally "CFG" or "ZIP", when the device is restarted, the configuration file will be reloaded into the device memory, called new current configuration. By default, when the current configuration is saved, the device will save the current configuration to a file named "vrpcfg.zip" in, and stored in the root directory of the external memory device.

2, save the current configuration

  Manually Save Configuration:

  

1 save [configuration-file]

  Manually save the configuration, direct save command, the default saved as "vrpcfg.zip", it represents unspecified save the file name.

  Backup configuration files:

1 save backup.zip

  The configuration file backup, file save the file "backup.zip" of the configuration file.

  Automatically saved configuration file:

2.1 periodically automatically save the configuration file

1 autosave interval on
2 autosave interval time

autosave interval on a function for periodically opening devices, autosave interval time period is set automatically saved, time for a specified period of time, in minutes, the default value 1440minus (24 hours).

2.2 periodically and automatically save

1 autosave time on
2 autosave time time-value

autosave time on opening devices is periodically auto-save feature, autosave time time-value is the time of the node settings are automatically saved, time-value of the specified time, the format hh: mm: ss default value 00:00:00.