Maintenance of the chamber of each member

  

  First, the [chamber ( http://www.ywxsh.com/) cleaning and maintenance of the housing of the external environment

  1, the internal temperature and humidity chamber must first eliminate the residue during operation.

  2, high and low voltage power distribution room many times over the years to clean up at least about, can use a vacuum cleaner to clean the room when the dust suction can be.

  3, the cabinet must also clean up many times over the years about the outside world, will be able to add soap to scrub clean up.

  Second, check the temperature and humidity chamber air humidifier and maintenance

  Water storage tank inside the air humidifier should replace them many times in January, to ensure water cleaning, humidifier basin should be cleaned several times a month, to ensure the smooth running water. Today, many laboratory applications is pure water, but still a month to clean-up related to the cup.

  Third, the dry bulb temperature and humidity chamber and regulating the water line inspection

  Water storage drum water level is not too high, the water in the cartridge water overflow or dry bulb temperature is too low to detect abnormal absorbent cloth, dry bulb temperature affect the accuracy of the water level is maintained about 6% full can. Adjusting the water in the water line of the cylinder, the adjustable height of the water in the cartridge. Similar experiments each done three or four times must be checked.

  Fourth, the dry bulb temperature and humidity chamber temperature detection cloth Removable

  When the detecting surface is not clean cloth or stiff, or to make a temperature control, again do MUST removable cloth before detecting the temperature and humidity of the actuating ball. Detection cloth for about four months to replace them several times, using the time to replace them clean towel to scrub the temperature sensor, when the newly detected removable cloth to clean and tidy.

  Fifth, eliminate dust cooler temperature and humidity chamber

  January coolers should maintenance, the use of cordless vacuum heat pipe cooler adhesion of dust suction line heat dissipating wire or the use of pressurized gas jet in addition to Gao dust.

  Six, overload protection device inspection chamber

  Runtime chamber, maintaining the superheat set to a high value by 20 ℃ ~ 30 ℃. When the temperature rises to set point experimental box of overheating safeguard of the power supply system of the electric heater is terminated, "OVERHEAT" overheat warning lights but the fan is still running, if the long-running and no one to look after, before running please try to really check overheating protection means, disposed is not safe [dry bulb temperature setting means overheat protection 120 ℃].