28436-2012 Terrestrial digital television broadcast exciter technical requirements and measurement methods

statement

This article is to study the technical requirements and measurement methods of GB-T 28436-2012 terrestrial digital television broadcast exciter. The study notes are compiled and shared in the hope that more people will benefit. If there is any infringement, please contact us in time.

1 Scope

This standard specifies
the technical requirements and measurement methods for VHF and UHF band terrestrial digital television broadcast exciters that comply with GB 20600-2006
. Any equivalent measurement method that can ensure the same measurement uncertainty may also be used. In case of dispute, this standard shall be used.

shall prevail.

This standard applies to
the design, production, use, operation and maintenance of terrestrial digital television broadcast exciters in VHF and UHF frequency bands.

2 Normative reference documents

The following documents are essential for the application of this document. For dated references, only the dated version applies to this
document. For undated referenced documents, the latest version (including all amendments) applies to this document.

GB/T 6113.101—2008 Specification for radio disturbance and immunity measurement equipment and measurement methods
Part 1-1: Radio disturbance

Interference and Immunity Measurement EquipmentMeasuring Equipment

GB 9254-2008 Radio disturbance limits and measurement methods for information technology equipment

GB/T 14433-1993 Technical regulations for color television broadcast coverage network

GB17625.1-2003 Electromagnetic compatibility limit harmonic current emission limit (equipment input current ≤16 A per phase)

GB17625.2—2007 Electromagnetic compatibility limits for
equipment with a rated current not greater than 16 A produced in public low-voltage power supply systems

Limitation of voltage changes, voltage fluctuations and flicker that may occur

GB/T 17626.2—2006 Electromagnetic compatibility test and measurement technology electrostatic discharge immunity test

GB/T 17626.3—2006 Electromagnetic compatibility testing and measurement technology Radio frequency electromagnetic field radiation immunity test

GB/T 17626.4-2008 Electromagnetic compatibility test and measurement technology Electrical fast transient burst immunity test

GB/T 17626.5—2008 Electromagnetic compatibility testing and measurement technology surge (impact) immunity test

GB/T 17626.6—2008 Electromagnetic compatibility test and measurement technology Conducted disturbance immunity induced by radio frequency fields

GB/T 17626.11-2008 Electromagnetic compatibility test and measurement technology
Immunity to voltage sag, short interruption and voltage change

test

GB 20600—2006 Digital television terrestrial broadcast transmission system frame structure, channel coding and modulation

GB/T 28436—2012 Terrestrial digital television broadcasting single frequency network adapter technical requirements and measurement methods

3 Terms, definitions, symbols and abbreviations

3.1 Terms and definitions

The following terms and definitions apply to this document.

3.1.1

frequency synthesisfrequency synthesis

By performing operations such as addition, subtraction, multiplication, and division with the reference frequency, a frequency signal with the same accuracy and stability as the reference frequency can be obtained.

3.1.2

effective bandwidth effective bandwith

The difference between the high-end and low-end frequencies corresponding to the amplitude attenuation of 3 dB relative to the signal center frequency.

GB/T 28436—2012

3.1.3

带肩 shoulder attenuation

The average power change of an out-of-band frequency point that deviates from the center frequency by a specified value relative to the center frequency point, in decibels (dB).

3.1.4

in band spectrum ripple _

The amplitude change of the average power of each frequency point of the in-band signal relative to the center frequency, in decibels (dB).

3.1.5

Out of band emissions _

The ratio of the out-of-band leakage signal power to the in-band digital signal power, in decibels (dB).

3.1.6

peak average power ratiopeak average power ratio

The ratio of the peak power to the average power of the modulated signal, in decibels (dB).

3.1.7

complementary cumulative distribution function complementary cumulative distribution
function

A function used to analyze the numerical statistical characteristics of the peak power of a modulated signal.

3.1.8

modulation error ratio modulation error ratio

The ratio of the sum of squares of the ideal symbol vector amplitudes of the modulated signal to the sum of squares of the symbol error vector amplitudes, in decibels (dB).

3.1.9

pseudorandom sequencepseudo random sequence

A binary data stream with good randomness and a correlation function close to white noise, and with predictable determinability and repeatability.

3.1.10

electromagnetic disturbanceelectromagnetic disturbance

Any electromagnetic phenomenon that may cause the performance of a device, equipment or system to degrade or cause damage to living or inanimate matter.

Note: Electromagnetic disturbance may be electromagnetic noise, unwanted noise or changes in the propagation medium itself.

[GB/T 4365—2003, definition 161-01-05]

3.1.11

[Electromagnetic] emission

The phenomenon of electromagnetic energy being emitted outward from a source.

[GB/T 4365—2003, definition 161-01-08]

3.1.12

emission(in radio communication )

The phenomenon of radio waves or signals being generated and sent out by a radio transmitter.

[GB/T 4365—2003, definition 161-01-09]

3.1.13

immunity(to a disturbance )

The ability of a device, equipment or system to face electromagnetic disturbances without degrading operational performance.

[GB/T 4365—2003, definition 161-01-20]

3.1.14

RF exclusion band _

In the electromagnetic compatibility measurement project, for
wireless equipment with an operating frequency lower than 2.7 GHz, or
equipment with an operating frequency above 2.7 GHz but with a radio frequency bandwidth extending below 2.7 GHz, electromagnetic emission tests and immunity are not required in the test-free frequency band. degree test, or no limit

value requirement.

GB/T 28436—2012

3.2 Symbols

The following symbols apply to this document.

Ac signal amplitude at center frequency

Amax The maximum amplitude of the in-band signal

Ami in-band signal minimum amplitude

Ap amplitude difference

C Number of carriers

fc signal center frequency

fcmax maximum output operating frequency

fcmin minimum output operating frequency

fkc operating frequency reference

Np local oscillator phase noise

P signal power

PpA lower adjacent channel in-band signal power

PMAGE mirror channel in-band signal power

Pmax maximum power of in-band signal

Pmi minimum power of in-band signal

PsH second harmonic channel in-band signal power

Pm third harmonic channel in-band signal power

Adjacent channel in-band signal power on PuA

Vpp peak-to-peak amplitude

Tdelay max maximum delay time

Tielay tmnsmitted Distribution network transmission delay time

3.3 Abbreviations

The following abbreviations apply to this document.

AC AC(Alternating Current)

ALC Auto Level Control

ASI Asynchronous Serial Interface

BER bit error rate (Bit Error Rate)

CCDF Complementary Cumulative Distribution Function

D/A Digital to Analog converting

FEC Forward Error Correction

IF Intermediate Frequency

MER Modulation Error Ratio

MFN Multi Frequency Network

MLC Manual Level Control

NR quasi-orthogonal coding (Nordstrom Robinson)

PAPR Peak Average Power Ratio

pps pulse per second

QAM Quadrature Amplitude Modulation

RBW Resolution Bandwith

GB/T 28436—2012

RF Radio Frequency

SFN Single Frequency Network

SIP Second frame Initialization Packet

TS Transport Stream

UHF Ultra High Frequency

VHF Very High Frequency

4 Technical requirements

4.1 Overview

The terrestrial digital TV broadcast exciter is the core of the terrestrial digital TV broadcast transmitter and an important part of the terrestrial digital TV broadcasting system
. The technical indicators of terrestrial digital TV broadcast exciters directly affect the performance of terrestrial digital TV broadcast transmitters and terrestrial digital TV

Network coverage effect.

The terrestrial digital TV broadcast exciter includes
functional modules such as baseband processing and D/A, frequency synthesis and up-conversion, RF output amplification and monitoring systems that comply with the regulations of GB 20600-2006, and completes the input
data stream from the baseband TS to the GB 20600-2006 standard. 2006 stipulated

Conversion of RF
signals for terrestrial digital television broadcasts in UHF or VHF frequency bands. The block diagram of the terrestrial digital television broadcast exciter is shown in Figure 1.

Note: IF monitoring output is an optional part.

Figure 1 Terrestrial digital television broadcast exciter block diagram

4.2 General requirements

4.2.1 Environmental conditions

Environmental conditions requirements are as follows:

a) Ambient temperature:

Normal working: 5℃~45℃;

Allowed working: 0℃~50℃.

b) Relative humidity:

Normal working: ≤90%(20℃);

GB/T 28436—2012

Allowed working: ≤95% (no condensation).

c) Atmospheric pressure: 86 kPa~106 kPa.

4.2.2 Working voltage

The working voltage requirements are as follows:

a) Voltage amplitude: 176 V ~ 264 V AC;

b) Voltage frequency: 50 Hz±1 Hz.

4.2.3 Interface requirements

The interface requirements are as follows:

a) Data input adopts ASI interface, BNC connector, female type, input impedance is 75Ω;

b) The 10 MHz clock input adopts BNC connector, female type, input impedance is 50Ω, AC coupling, Vpp≥600
mV;

c) 1 pps input adopts BNC connector, female type, TTL level, input impedance is 50 Ω;

d) The RF output uses SMA or BNC or N-type connector, female type, and the output impedance is 50 Ω;

e) The monitoring output adopts SMA or BNC connector, female type, and the output impedance is 50 Ω;

f) The remote control and monitoring interface adopts RS232 or RS485 or RJ45. RS232 adopts DB9
connector, male type; RS485 adopts DB9 connector, male or female type.

4.3 Functional requirements

4.3.1 Working mode

Supports
all working modes specified in GB 20600-2006. The first superframe when the exciter starts modulating in various operating modes is

Number 0 is an even-numbered superframe.

Please refer to Appendix A for the maximum net code rate of the system (8 MHz bandwidth) under various operating modes.

4.3.2 Stream backup and switching

Provide at least two channels of ASI data input to back up each other, and have manual and automatic switching functions.

4.3.3 Pre-calibration

With linear and non-linear pre-correction functions. Through pre-correction, the spectral characteristics of the transmitter output signal can be improved.

4.3.4 Operating frequency range

Comply with GB/T 14433-1993 regulations.

4.3.5 Frequency reference source

When there is an external reference source, the exciter will give priority to using the external reference source; when there is no external reference source, the exciter will enable the internal reference source. Internal and external reference

Sources can be switched manually or automatically.

4.3.6 Power control

Provides manual level control (MLC) and automatic level control (ALC) power control methods.

4.3.7 Monitoring and alarming

Provide real-time monitoring and alarm functions. The monitoring system detects the working status of each component of the exciter and gives alarm instructions when abnormal conditions occur.

GB/T 28436—2012

display, the alarm status can be queried through the remote control port. The monitoring content and alarm conditions are shown in Table 1.

Table 1 Monitoring content and alarm conditions

Monitor content

Alarm condition

Code stream input

Input interruption, non-TS stream format, input bit rate is greater than the maximum net bit rate

reference clock

Invalid

RF local oscillator

Lost lock

Temperature alarm

overheat

SFN status

Unable to parse SIP

4.3.8 Automatic protection

Provide automatic protection function. When some parts of the exciter have serious failures (such as output overload, power amplifier overheating, etc.), or when the
exciter is damaged due to external reasons, or when the TS
flow is interrupted, the monitoring system will automatically cut off the RF output of the exciter or shut down, avoid

avoid further damage.

4.3.9 Monitoring output

Provides 10 MHz monitoring output, local oscillator monitoring output, IF monitoring output (optional) and RF
monitoring output. Monitor output signals for system

System equipment performance measurement, real-time monitoring and broadcast network operation and maintenance.

4.3.10 Networking method

Support multi-frequency network (MFN) or single frequency network (SFN) networking mode, where the SFN networking mode requirements should comply with
GB/T 28436-2012

relevant regulations.

In single frequency network mode, in order to ensure that the data transmitted by all exciters connected to the network is consistent, the detected SIP
packets should be replaced with the MPEG-2
empty packet format. The four bytes of the empty packet header are in hexadecimal. Expressed as 0x47, 0x1F, 0xFF, 0x10, the remaining empty packet

184 bytes are all 0xFF, see Figure 2. At the same time, the empty packet after the SIP
packet replacement is used as the first data packet to start modulation.

1 2 3 4 5~188

0x47

(AXIF

OxFT

0x10

OxIiF…OxliF

Figure 2 The empty packet format replaced by SIP packets in single frequency network mode

In single frequency network mode, "Tdelaymax" includes the delay required for baseband processing of the exciter. The
setting range of Tieaymax is (Taeay transmitted²+30.000ms) to 999.999 ms. The 30.000 ms here
is the agreed maximum baseband processing time of the exciter. Delay. In order to
ensure that the modulated data output of various exciters is consistent at all times, it should be ensured that the
first symbol of the signal frame where the empty packet after the current SIP packet is replaced is
output at the Teymax time after being processed by shaping filtering. The output time of this symbol The error with Teymax time is within ±1μs

within.

4.4 Performance requirements

The performance requirements for terrestrial digital television broadcast exciters are shown in Table 2.

  1. The maximum delay time refers to the time for each transmitter's TS program stream to be
    uniformly transmitted relative to 1 pps of the reference clock signal source.

  2. The distribution network transmission delay time refers to
    the time it takes for the TS program stream to be transmitted through the distribution network after being sent out by the single frequency network adapter.

GB/T 28436—2012

Table 2 Terrestrial digital television broadcast exciter performance requirements

serial number

project

index

1

working frequency

Comply with the relevant provisions of GB/T 14433-1993

2

Single frequency network mode frequency adjustment step size

1 Hz

3

frequency accuracy

For MFN mode, frequency accuracy: ±100 Hz;

For SFN mode, frequency accuracy: ±1Hz

4

Frequency stability (3 months)

When using internal reference source, frequency stability: 1×10-7;

When using an external reference source, frequency stability: 1×10-10

5

Output Power

≥0 dBm

6

Output power stability (24 hours)

Within ±0.3 dB

7

RF effective bandwidth

7.56 MHz

8

Roll-off coefficient

0.05

9

Signal shoulder (f. ±4.2 MHz)

≤-48 dBc

10

In-band spectral unevenness (f. ±3.591 MHz)

Within ±0.5 dB

11

out-of-band spurious

Adjacent channel in-band unwanted transmit power

50 dB below in-band signal power

Adjacent channel out-of-band unwanted transmit power

55 dB below in-band signal power

12

local oscillator phase noise

≤-60 dBc/Hz (at 10 Hz);

≤-75 dBc/Hz (at 100 Hz);

≤ -85 dBc/Hz (at 1kHz);

≤ -95 dBc/Hz (at 10kHz);

≤ - 110 dBc/Hz (at 100kHz);

≤ - 120 dBc/Hz (at 1MHz)

13

Peak to average power ratio (PAPR)

Meets CCDF curve template requirements, see Figure 3

14

Modulation Error Rate (MER)

≥36 dB

15

Single frequency network delay adjustment range

0 ms~969.9999 ms

16

The error between the first symbol output moment and Tdelay max in single frequency network mode

±1μs

17

Single frequency network delay adjustment step

100 ns

Cumulative board rate and peak-to-average power ratio/dB

3 CCDF 曲线模板

GB/T 28436—2012

4.5 电磁兼容性要求

4.5.1 免测频段

地面数字电视广播激励器免测频段为激励器被指定的工作频段。

4.5.2 电磁环境

如无特别声明,地面数字电视广播激励器使用的电磁环境应属 E5,
故下文所列发射限值及抗扰度

测量级别均对照E5 等级执行。

电磁环境详细说明参见附录 B。

4.5.3 端口

对应图1,将地面数字电视广播激励器的各功能接口归类为电磁兼容试验端口,见表3。

电磁兼容试验端口详细说明参见附录B。

3 地面数字电视广播激励器接口归类

电磁兼容试验端口的归类

对应激励器接口

信号/控制端口"

ASI输入

10 MHz参考输入
1 pps

交流电源端口

电源

机壳端口

机壳

通信端口b

接地端口"

直流电源端口

天线端口b

此类端口的电磁兼容性试验为地面数字电视广播激励器必选项目。

当受试设备具备该端口时,可依照GB/T 19954.1—2005或GB/T 19954.2—2005要求进行电磁兼容性试验,

否则不作要求。

4.5.4 电磁发射限值要求

4.5.4.1 机壳端口

地面数字电视广播激励器机壳端口的辐射发射限值见表4。

4 地面数字电视广播激励器机壳端口的辐射发射限值

测量项目

频率范围

限值

E1~E3

限值

E4~E5

适用标准

射频电磁场(3m)

30 MHz~230 MHz 40 dBμV/m

准峰值

50 dBμV/m

准峰值

GB 9254—2008

230 MHz~1 GHz 47 dBμV/m

准峰值

57 dBμV/m

准峰值

GB/T 28436—2012

4.5.4.2 交流电源端口

地面数字电视广播激励器的交流电源端口传导发射限值见表5。

5 地面数字电视广播激励器交流电源端口传导发射限值

测量项目

频率范围

限值

E1~E3

限值

E4~E5

适用标准

谐波电流

按照适用标准

按照适用标准

按照适用标准

GB 17625.1—2003

电压波动

按照适用标准

按照适用标准

按照适用标准

GB 17625.2—2007

传导发射"

0.15 MHz~0.5 MHz 66 dB~56 dBμV准峰值 56 dB~46 dBμV平均值 79 dBμV准峰值 66 dBuV平均值

GB 9254—2008

0.5 MHz~5 MHz 56 dBμV准峰值 46 dBμV平均值 73 dBμV准峰值 60 dBμV平均值
5 MHz~30 MHz 60 dBμV准峰值 50 dBμV平均值

限值随频率的对数线性减少。

4.5.5 电磁抗扰度试验要求

4.5.5.1 性能判据

每项抗扰度试验的结果评价基于下面的标准:

a) 性能判据 A: 激励器在技术要求限值内性能正常;

b) 性能判据 B:激励器功能或性能暂时降低或丧失但能自行恢复;

c) 性能判据C:
激励器功能或性能暂时降低或丧失但在操作者干预或系统复位后恢复;

d) 性能判据D:
激励器因设备元件或软件损坏或数据丢失而造成不能自行恢复至正常状态。

4.5.5.2 机壳端口

地面数字电视广播激励器的机壳端口抗扰度要求见表6。

6 地面数字电视广播激励器机壳端口的抗扰度要求

试验项目

频率范围

测量等级

E1~E3

测量等级

E4

测量等级

E5

适用标准

性能判据

射频电

磁场"

(3 m)

80 MHz~1 GHz 3 V/m 1 V/m 10 V/m

GB/T 17626.3—

2006

A

1.4 GHz~2 GHz 3 V/m

无对应测量

3 V/m
2.0 GHz~2.7 GHz 1 V/m

无对应测量

1 V/m

静电放电

按照适用标准

4 kV:接触放电; 8 kV:空气放电

2kV:接触放电;

4 kV:空气放电

4kV:接触放电;

8 kV:空气放电

GB/T 17626.2—

2006

B

载波信号采用频率为1kHz,80%幅度调制的正弦波信号;测量等级指非调制载波信号的值。

GB/T 28436—2012

4.5.5.3 信号或控制端口

地面数字电视广播激励器的信号或控制端口的抗扰度要求见表7。

7 地面数字电视广播激励器信号或控制端口的抗扰度要求

试验项目

频率范围

测量等级

E1~E3

测量等级

E4

测量等级

E5

适用标准

性能判据

电快速瞬变脉冲

群共模 … ·b

按照适用标准

0.5 kV(峰值) 1 kV(峰值)

GB/T 17626.4—

2008

B

射频共模 · de.

0.15 MHz~80 MHz 3 V 1 V 10 V

GB/T 17626.6—

2008

A

仅应用于连接电缆的端口,其总长度根据厂商的要求超过3m的情况。

单个脉冲的上升时间为5ns,脉冲持续时间(50%值)为50ns,重复频率为5kHz。

载波信号采用频率为1kHz,80%幅度调制的正弦波信号;测量等级指非调制载波信号的值。

只适用于接电缆的端口,其总长度根据厂商的要求可能超过1m的情况。

e对于天线端口,按照GB/T 9383—2008。

源阻抗=150 Ω。

4.5.5.4 交流电源端口

地面数字电视广播激励器的交流电源端口抗扰度要求见表8。

8 地面数字电视广播激励器交流电源端口的抗扰度要求

试验项目

频率范围

测量等级

E1~E3

测量等级

E4

测量等级

E5

适用标准

性能

判据

电快速瞬变脉

冲群*,b

按照适

用标准

1 kV(峰值) 0.5 kV(峰值) 2 kV(峰值)

GB/T 17626.4—

2008

B

射频共模c ·d

0.15 MHz

~80 MHz

3 V 1 V 10 V

GB/T 17626.6—

2008

A

浪涌

按照适

用标准

共模:1kV(峰值)

差模:0.5 kV(峰值)

或4.5倍额定电压,

以较少者为准

共模:0.5 kV

(峰值)

共模:2 kV

(峰值)

GB/T 17626.5—

2008

B

电压跌落°

0.5个周期,减少30%

GB/T 17626.11—

2008

B

5个周期,减少60%

电压中断

5秒内,减小超过95%

C

单个脉冲的上升时间为5ns,脉冲持续时间(50%值)为50 ns,重复频率为5kHz。

对于输入端口使用CDN,见GB/T 17626.4—2008,而容性耦合钳用于输出端口。

载波信号采用频率为1kHz,80%幅度调制的正弦波信号;测量等级指非调制载波信号的值。

源阻抗=150 Ω。

电压在零交叉点变化。

GB/T 28436—2012

5 测量方法

5.1 工作模式

5.1.1 测量框图

工作模式测量需要的设备包括码流发生器、地面数字电视接收机、显示器或误码分析仪,测量框图

见图4。

4 地面数字电视广播激励器工作模式测量框图

5.1.2 测量步骤

测量步骤如下:

a) 如图4所示连接测量系统。

b) 设置激励器工作于GB 20600—2006 规定的工作模式之一。

c)
设置码流发生器发送伪随机序列或测量图像序列,码率略低于激励器此时工作模式下的最大
净码率。

d) 观察误码分析仪误码率(BER)
或显示器图像,判断接收机工作是否正常。接收机工作正常判 断标准:

● 采用伪随机序列时,误码分析仪的1 min BER 显示为0;

● 采用测量图像序列,显示器输出图像无损伤。

e) 改变激励器工作模式,重复步骤 c)~d),直至遍历GB 20600—2006
规定的所有工作模式。

5.2 工作频率

5.2.1 测量框图

工作频率测量需要的设备包括码流发生器和频率计,测量框图见图5。

码流发生器

IS信号

地面数字息视

广播激励器

RT 信号

频率计

5
地面数字电视广播激励器工作频率、频率准确度和频率稳定度测量框图

5.2.2 测量步骤

测量步骤如下:

a) 如图5所示连接测量系统;

b) 设置激励器工作于GB 20600—2006 规定的工作模式之一;

c)
设置码流发生器发送伪随机序列或测量图像序列,码率略低于激励器此时工作模式下的最大
净码率;

GB/T 28436—2012

d) 设置激励器只输出载波射频信号;

e) 用频率计测量载波射频信号频率,记为激励器工作频率。

5.3 频率准确度

5.3.1 测量框图

频率准确度测量需要的设备包括码流发生器和频率计,测量框图见图5。

5.3.2 测量步骤

测量步骤如下:

a) 如图5所示连接测量系统;

b) 设置激励器工作于GB 20600—2006 规定的任意一种工作模式;

c)
设置码流发生器发送伪随机序列或测量图像序列,码率略低于激励器此时工作模式下的最大
净码率;

d) 设置激励器只输出载波射频信号;

e)
用频率计测量载波射频信号频率,频率准确度为载波射频信号频率与标称工作频率之差。

5.4 频率稳定度

5.4.1 测量框图

频率稳定度测量需要的设备包括码流发生器和频率计,测量框图见图5。

5.4.2 测量步骤

测量步骤如下:

a) 如图5所示连接测量系统;

b) 设置激励器工作于GB 20600—2006 规定的任意一种工作模式;

c)
设置码流发生器发送伪随机序列或测量图像序列,码率略低于激励器此时工作模式下的最大
净码率;

d) 设置激励器只输出载波射频信号;

e) 用频率计读取载波射频信号记为frc;

f)
在3个月周期内,每隔1周测量1次载波射频信号,其中最大和最小输出工作频率记为fcmax和
fcmm,频率稳定度为fcmin与 frc之差到 fcmax与 fc 之差。

5.5 输出功率

5.5.1 测量框图

输出功率测量需要的设备包括码流发生器和频谱分析仪,测量框图见图6。

码流发生器

TS信号

地面数字电视

广播激励器

RF 信号

频谱分析仪

6
输出功率、输出功率稳定度、射频有效带宽、滚降系数、信号带肩、

带内频谱不平坦度、邻频道带内无用发射功率、邻频道带外无用发射功率和本振相位噪声测量框图

GB/T 28436—2012

5.5.2 测量步骤

测量步骤如下:

a) 如图6所示连接测量系统;

b) 设置激励器工作于GB 20600—2006 规定的任意一种工作模式;

c)
设置码流发生器发送伪随机序列或测量图像序列,码率略低于激励器此时工作模式下的最大
净码率;

d) 设置频谱分析仪中心频率为激励器工作频率,测量带宽为8 MHz,
测量信号功率,即为输出 功率。

5.6 输出功率稳定度

5.6.1 测量框图

输出功率稳定度测量需要的设备包括码流发生器和频谱分析仪,测量框图见图6。

5.6.2 测量步骤

测量步骤如下:

a) 如图6所示连接测量系统;

b) 设置激励器工作于GB 20600—2006 规定的任意一种工作模式;

c)
设置码流发生器发送伪随机序列或测量图像序列,码率略低于激励器此时工作模式下的最大
净码率;

d) 设置频谱分析仪中心频率为激励器工作频率,测量带宽为8 MHz,
测量信号功率P;

e) 在24小时内,每小时测量1次信号功率,其中最大和最小信号功率分别记为
Pmx 和 Pmin,输出 功率稳定度为 Pmi 与 P 之差至Pmax与 P 之差。

5.7 射频有效带宽

5.7.1 测量框图

射频有效带宽测量需要的设备包括码流发生器和频谱分析仪,测量框图见图6。

5.7.2 测量步骤

测量步骤如下:

a) 如图6所示连接测量系统;

b) 设置激励器工作于GB 20600—2006 规定的双导频工作模式;

c)
设置码流发生器发送伪随机序列或测量图像序列,码率略低于激励器此时工作模式下的最大
净码率;

d) 设置频谱分析仪中心频率为激励器工作频率,RBW 设置为1 kHz,VBW
设置为1 kHz;

e) 分别读取高端、低端导频频率fu、fp, 射频有效带宽为fm 与 fu 之差。

5.8 滚降系数

5.8.1 测量框图

滚降系数测量需要的设备包括码流发生器和频谱分析仪,测量框图见图6。

GB/T 28436—2012

5.8.2 测量步骤

测量步骤如下:

a) 如图6所示连接测量系统;

b) 设置激励器工作于GB 20600—2006 规定的任意一种工作模式;

c)
设置码流发生器发送伪随机序列或测量图像序列,码率略低于激励器此时工作模式下的最大
净码率;

d) 设置频谱分析仪中心频率为激励器工作频率,RBW 设置为3 kHz,VBW
设置为3 kHz, 测量 中心频率处信号幅度记为Ac;

e) 分别测量高端、低端幅度为Ac-40
dB点频率,两者的差值为射频占用带宽,滚降系数为占用
带宽与有效带宽之差和有效带宽的比值。

5.9 信号带肩

5.9.1 测量框图

信号带肩测量需要的设备包括码流发生器和频谱分析仪,测量框图见图6。

5.9.2 测量步骤

测量步骤如下:

a) 如图6所示连接测量系统;

b) 设置激励器工作于GB 20600—2006 规定的任意一种工作模式;

c)
设置码流发生器发送伪随机序列或测量图像序列,码率略低于激励器此时工作模式下的最大
净码率;

d) 设置频谱分析仪中心频率为激励器工作频率,RBW 设置为3 kHz,VBW
设置为3 kHz, 测量 信号中心频率fc 处信号幅度记为Ac;

e) 分别测量fc±4.2MHz 处信号幅度,信号带肩为fc±4.2 MHz处信号幅度与Ac
的差值。

5.10 带内频谱不平坦度

5.10.1 测量框图

带内频谱不平坦度测量需要的设备包括码流发生器和频谱分析仪,测量框图见图6。

5.10.2 测量步骤

测量步骤如下:

a) 如图6所示连接测量系统;

b) 设置激励器工作于GB 20600—2006 规定的任意一种工作模式;

c)
设置码流发生器发送伪随机序列或测量图像序列,码率略低于激励器此时工作模式下的最大
净码率;

d) 设置频谱分析仪中心频率为激励器工作频率,RBW 设置为3 kHz,VBW
设置为3 kHz, 测量

平均次数不少于100次,测量中心频率处平均幅度记为Ac;

e) 测量带内最大和最小平均幅度值分别记为Amax和 Amm,
带内频谱不平坦度为Amm 与 Ac 的差

到 Amax与 Ac 的差。

5.11 邻频道带内无用发射功率

5.11.1 测量框图

邻频道带内无用发射功率测量需要的设备包括码流发生器和频谱分析仪,测量框图见图6。

GB/T 28436—2012

5.11.2 测量步骤

测量步骤如下:

a) 如图6所示连接测量系统;

b) 设置激励器工作于GB 20600—2006 规定的任意一种工作模式;

c)
设置码流发生器发送伪随机序列或测量图像序列,码率略低于激励器此时工作模式下的最大
净码率;

d) 将频谱分析仪中心频率设置为激励器工作频率,测量带宽为8 MHz,
测量信号功率记为 P;

e)
设置频谱分析仪中心频率为激励器工作频率的上、下邻频道中心,测量带宽为8
MHz, 分别测 量上、下邻频功率Pua 和 PpA,邻频道带内无用发射功率为 PuA 和
PpA两者较大值与P 的差。

5.12 邻频道带外无用发射功率

5.12.1 测量框图

邻频道带外无用发射功率测量需要的设备包括码流发生器和频谱分析仪,测量框图见图6。

5.12.2 测量步骤

测量步骤如下:

a) 如图6所示连接测量系统;

b) 设置激励器工作于 GB 20600—2006 规定的任意一种工作模式;

c)
设置码流发生器发送伪随机序列或测量图像序列,码率略低于激励器此时工作模式下的最大
净码率;

d) 设置频谱分析仪中心频率为激励器工作频率,测量带宽为8 MHz,
测量信号功率记为 P;

e)
频谱分析仪中心频率分别设置为二、三次谐波频道和镜像频道中心频率(由上变频方式确定),
测量带宽为8 MHz, 分别测量上述信号功率,记为 PsH、P
、PMAGE,邻频道带外无用发射功率 为PsH、PH、PMAGE三者最大值与 P 的差。

5.13 本振相位噪声

5.13.1 测量框图

本振相位噪声测量需要的设备包括码流发生器和频谱分析仪,测量框图见图6。

5.13.2 测量步骤

5.13.2.1 测量方法选择

频谱分析仪带相位噪声测量功能采用测量方法一;频谱分析仪无相位噪声测量功能采用测量方

法二。

5.13.2.2 测量方法一

测量步骤如下:

a) 如图6所示连接测量系统;

b) 设置激励器工作于GB 20600—2006 规定的任意一种工作模式;

c)
设置码流发生器发送伪随机序列或测量图像序列,码率略低于激励器此时工作模式下的最大
净码率;

GB/T 28436—2012

d) 设置激励器只输出载波射频信号;

e)
选择相位噪声测量功能,设置频谱分析仪中心频率为标称工作频率,测量带宽设置为2
MHz, 打印和保存本振相位噪声测量结果。

5.13.2.3 测量方法二

测量步骤如下:

a) 如图6所示连接测量系统;

b) 设置激励器工作于 GB 20600—2006 规定的任意一种工作模式;

c)
设置码流发生器发送伪随机序列或测量图像序列,码率略低于激励器此时工作模式下的最大
净码率;

d) 设置激励器只输出载波射频信号;

e)
设置频谱分析仪中心频率为标称工作频率,根据测量频率点位置不同,适当设置
RBW, 分别测 量10 Hz、100 Hz、1kHz、10kHz、100kHz和 1 MHz
频率处幅度相对标称工作频率处幅度的 差值,记为Ap,
并根据式(1)换算得到各频率点相位噪声N。。

N,=A,- 10lg(1.2RBW/1 Hz)+2.5 ………………………… (1)

5.14 峰值平均功率比

5.14.1 测量框图

峰值平均功率比(PAPR)
测量需要的设备包括码流发生器和矢量分析仪,测量框图见图7。

码流发生器

TS信号

地面数字电视

广播激励器

RF 信号

矢量分析仪

7 峰值平均功率比测量框图

5.14.2 测量步骤

测量步骤如下:

a) 如图7所示连接测量系统;

b) 设置激励器工作于 GB 20600—2006 规定的任意一种工作模式;

c)
设置码流发生器发送伪随机序列或测量图像序列,码率略低于激励器此时工作模式下的最大
净码率;

d) 设置矢量分析仪中心频率为激励器工作频率,分析带宽为8 MHz;

e) 选择矢量分析仪的CCDF 测量功能,统计样本设置为100000,在显示的 CCDF
曲线稳定后,

保存并打印CCDF 曲线,读取峰值平均功率比。

5.15 调制误差率

5.15.1 测量框图

调制误差率(MER)
测量需要的设备包括码流发生器和调制误差率测量仪,测量框图见图8。

GB/T 28436—2012

码流发生器

TS信号

地面数字电视

广播激励器

RI信号

调制误差率

测试仪

8 调制误差率测量框图

5.15.2 测量步骤

测量步骤如下:

a) 如图8所示连接测量系统;

b) 设置激励器工作于GB 20600—2006 规定的任意一种工作模式;

c)
设置码流发生器发送伪随机序列或测量图像序列,码率略低于激励器此时工作模式下的最大
净码率;

d) 调制误差率测量仪工作频率设置为激励器工作频率,读取调制误差率值。

5.16 单频网延时调整范围

5.16.1 测量框图

单频网延时调整范围测量需要的设备包括码流发生器、基准时钟信号源、地面数字电视广播单频网

适配器、地面数字电视接收机、显示器或误码分析仪,测量框图见图9。

9 单频网延时调整范围测量框图

5.16.2 测量步骤

测量步骤如下:

a) 如图9所示连接测量系统;

b)
设置码流发生器发送伪随机序列或测量图像序列,码率略低于激励器此时工作模式下的最大
净码率;

c) 设置单频网适配器工作于 GB 20600—2006 规定的任意一种工作模式;

d) 观察激励器是否能够解析 SIP
包,并正确设置工作模式保证接收机正常工作;

e)
通过单频网适配器改变激励器延时设置,在保证接收机正常工作情况下,观察并记录单频网延
时调整范围。

GB/T 28436—2012

5.17 单频网模式下第一符号输出时刻与Tichay may的误差

5.17.1 测量框图

单频网模式下第一符号输出时刻与Telay
max的误差测量需要的设备包括码流发生器、基准时钟信号
源、地面数字电视广播单频网适配器、地面数字电视参考激励器、地面数字电视测量接收机和数字示波

器,测量框图见图10。

1 0 第一符号输出时刻与 Tahy
ma的误差测量框图

5.17.2 测量步骤

测量步骤如下:

a) 如图10所示连接测量系统;

b)
设置码流发生器发送伪随机序列或测量图像序列,码率略低于激励器此时工作模式下的最大
净码率;

c) 设置单频网适配器工作于 GB 20600—2006 规定的任意一种工作模式;

d) 观察激励器是否能够解析 SIP
包,并正确设置工作模式保证接收机正常工作;

e)
观察数字示波器中两路时域帧头相关结果,利用示波器量出单频网模式下受试激励器与参考
激励器的相关峰延时,此延时即为单频网模式下第一符号输出时刻与 Ty
max的误差。

5.18 电磁兼容性试验测量方法

各项电磁兼容性试验的试验条件、试验布置、场地要求、测量方法及测量仪器,如果在本标准中未提

及或说明,应符合表4~表8中各适用标准的要求及GB/T6113.101—2008
中相关要求。

电磁兼容发射测试时,激励器输出设置为最大输出状态。

电磁兼容抗扰度测试时,激励器输出设置为典型输出状态。

5.18.1 机壳端口辐射发射试验

5.18.1.1 测量框图

机壳端口的辐射发射试验的测量框图见图11。

GB/T 28436—2012

图11 机壳端口的辐射发射试验测量框图

5.18.1.2 测量步骤

测量步骤如下:

a) 如图11所示连接测量系统,传感器为天线及电磁兼容测量接收机;

b) 设置激励器工作于GB 20600—2006 规定的任意一种工作模式;

c)
设置码流发生器发送测量图像序列,码率略低于激励器此时工作模式下的最大净码率,在整个
试验过程中,观察显示器,确认系统处于正常工作状态;

d) 根据 GB
9254—2008第10章中的测量方法和场地布置进行试验:除激励器以外的辅助设备
均应通过加磁环的、屏蔽性良好的线缆连接并置于暗室环境之外,或在保证辅助设备所引入的
环境噪声低于限值线6 dB
以上时允许辅助设备放置在暗室以内。天线及电磁兼容测量接收
机采集激励器的辐射骚扰信号;

e) 用带有峰值检波器的电磁兼容测量接收机在30 MHz~1000 MHz
频率范围内进行初步

测量;

f) 在每一个测量频率,在接地平板上方1 m~4m
的范围内调整天线的高度,以获得最大的指

示值;

g) 在测量过程中,对激励器进行360度旋转,以寻找辐射场强最大的方向;

h) 依次将天线改变为水平或垂直极化方式,以寻找最大的场强读数;

i)
对照各频点的限值,对初测时峰值检波器读值超出相应频点准峰值限值的位置,使用电磁兼容
测量接收机的准峰值检波器进行读数。

5.18.2 交流电源端口传导发射试验

5.18.2.1 测量框图

交流电源端口传导发射试验的测量框图见图12。

图12 交流电源端口传导发射试验测量框图

GB/T 28436—2012

5.18.2.2 测量步骤

5.18.2.2.1 电压波动

测量步骤如下:

a) 如图12所示连接测量系统,传感器为单相谐波闪烁分析仪;

b) 设置激励器工作于GB 20600—2006 规定的任意一种工作模式;

c)
设置码流发生器发送测量图像序列,码率略低于激励器此时工作模式下的最大净码率,在整个
试验过程中,观察显示器,确认系统处于正常工作状态;

d)
单相谐波闪烁分析仪连接专用的单相交流电源为激励器提供高质量的供电电源,并采集激励
器的电压波动、电压变化和闪烁骚扰信号;

e) 根据GB/T 17625.1—2003
的测量方法和场地布置进行试验,由谐波闪烁分析仪得到测量

结果。

5.18.2.2.2 谐波电流

测量步骤如下:

a) 如图12所示连接测量系统,传感器为单相谐波闪烁分析仪;

b) 设置激励器工作于GB 20600—2006 规定的任意一种工作模式;

c)
设置码流发生器发送测量图像序列,码率略低于激励器此时工作模式下的最大净码率,在整个
试验过程中,观察显示器,确认系统处于正常工作状态;

d)
单相谐波闪烁分析仪连接专用的单相交流电源为激励器提供高质量的供电电源,并采集激励
器的谐波电流骚扰信号;

e) 根据GB/T17625.2—2007
的测量方法和场地布置进行试验,由谐波闪烁分析仪得到测量

结果。

5.18.2.2.3 传导发射

测量步骤如下:

a) 如图12所示连接测量系统,传感器为人工电源网络及电磁兼容测量接收机;

b) 设置激励器工作于GB 20600—2006 规定的任意一种工作模式;

c)
设置码流发生器发送测量图像序列,码率略低于激励器此时工作模式下的最大净码率,在整个
试验过程中,观察显示器,确认系统处于正常工作状态;

d)
将地面数字电视激励器的电源电缆连接到人工电源网络,电磁兼容测量接收机使用一个脉冲
限幅器连接到人工电源网络,采集电源端子的传导骚扰信号;

e) 根据GB
9254—2008第9章中的测量方法和场地布置进行试验,地面数字电视激励器应布置
于水平参考接地平板上方0.8 m
的非导电桌子上,背面应距离垂直参考接地平板0.4 m, 垂直
参考接地平板应搭接到水平垂直参考接地平板上,所使用的人工电源网络须搭接到水平参考
接地平板上;

f)
用带有平均值和准峰值检波器的电磁兼容测量接收机进行扫描测量,频率范围为150
kHz~

30 MHz,记录测量结果。

5.18.3 机壳端口抗扰度试验

5.18.3.1 测量框图

机壳端口辐射抗扰度试验的测量框图见图13。

GB/T 28436—2012

机壳端口静电放电扰度试验的测量框图见图14。

图13 机壳端口辐射抗扰度试验测量框图

图14 机壳端口静电放电扰度试验测量框图

5.18.3.2 测量步骤

5.18.3.2.1 射频电磁场

测量步骤如下:

a)
如图13所示连接测量系统,电磁骚扰模拟器为信号源、放大器及发射天线,应将辅助设备置于
测量环境之外,以确保其不受到所施加的辐射骚扰信号的影响;

b) 设置激励器工作于GB 20600—2006 规定的任意一种工作模式;

c)
设置码流发生器发送测量图像序列,码率略低于激励器此时工作模式下的最大净码率,在模
拟施加电磁骚扰之前,观察显示器,确认系统处于正常工作状态;

d) 根据GB/T 17626.3—2006
的测量方法和场地布置进行试验,按照表6规定的等级给激励器
施加射频电场骚扰;

e)
4.5.5.1 要求判定激励器机壳
端口射频电磁场抗扰度。

5.18.3.2.2 静电放电

测量步骤如下:

a)
如图14所示连接测量系统,电磁骚扰模拟器为静电放电枪,应使用空间发射/接收方式作为信
号传输手段,以确保地面数字电视接收机及显示器不受到所施加的静电放电骚扰信号的影响;

b) 设置激励器工作于GB 20600—2006 规定的任意一种工作模式;

c)
设置码流发生器发送测量图像序列,码率略低于激励器此时工作模式下的最大净码率,在模拟

GB/T 28436—2012

施加电磁骚扰之前,观察显示器,确认系统处于正常工作状态;

d) 根据GB/T 17626.2—2006
的测量方法和场地布置进行试验,按照表6规定的等级给激励器
施加静电放电骚扰;

e)
4.5.5.1 要求判定激励器机壳
端口静电放电抗扰度。

5.18.4 信号或控制端口的抗扰度试验

5.18.4.1 测量框图

信号或控制端口传导抗扰度试验的测量框图见图15。

图15 信号或控制端口传导抗扰度试验测量框图

5.18.4.2 测量步骤

5.18.4.2.1 电快速瞬变脉冲群

测量步骤如下:

a)
如图15所示连接测量系统,电磁骚扰模拟器为电快速瞬变脉冲群模拟器,应使用空间发射/接
收方式作为信号传输手段,以确保地面数字电视接收机及显示器不受到所施加的电快速瞬变
脉冲群骚扰信号的影响;

b) 设置激励器工作于 GB 20600—2006 规定的任意一种工作模式;

c)
设置码流发生器发送测量图像序列,码率略低于激励器此时工作模式下的最大净码率,在模拟
施加电磁骚扰之前,观察显示器,确认系统处于正常工作状态;

d) 根据GB/T 17626.4—2008
的测量方法和场地布置进行试验,按照表7规定的等级给激励器
施加电快速瞬变脉冲群骚扰。脉冲群抗干扰模拟器连接电容耦合夹,通过耦合夹将骚扰信号
耦合到地面数字电视激励器的信号或控制电缆上;

e)
4.5.5.1 要求判定激励器信号
或控制端口电快速瞬变脉冲群抗扰度。

5.18.4.2.2 射频共模

测量步骤如下:

a)
如图15所示连接测量系统,电磁骚扰模拟器为连续波模拟器,应使用空间发射/接收方式作为
信号传输手段,以确保地面数字电视接收机及显示器不受到所施加的射频共模骚扰信号的

影响;

GB/T 28436—2012

b) 设置激励器工作于GB 20600—2006 规定的任意一种工作模式;

c)
设置码流发生器发送测量图像序列,码率略低于激励器此时工作模式下的最大净码率,在模拟
施加电磁骚扰之前,观察显示器,确认系统处于正常工作状态;

d) 根据GB/T 17626.6—2008
的测量方法和场地布置进行试验,按照表7规定的等级给激励器
施加射频共模骚扰:连续波模拟器连接6 dB
衰减器,再通过耦合网络将骚扰信号耦合到地面
数字电视激励器的信号或控制电缆上;

e)
4.5.5.1 要求判定激励器信号
或控制端口射频共模抗扰度。

5.18.5 交流电源端口的抗扰度试验

5.18.5.1 测量框图

交流电源端口传导抗扰度试验的测量框图见图16。

图16 交流电源端口传导抗扰度试验测量框图

5.18.5.2 测量步骤

5.18.5.2.1 电快速瞬变脉冲群

测量步骤如下:

a)
如图16所示连接测量系统,电磁骚扰模拟器为电快速瞬变脉冲群模拟器,应使用空间发射/接
收方式作为信号传输手段,以确保地面数字电视接收机及显示器不受到所施加的电快速瞬变
脉冲群骚扰信号的影响;

b) 设置激励器工作于GB 20600—2006 规定的任意一种工作模式;

c)
设置码流发生器发送测量图像序列,码率略低于激励器此时工作模式下的最大净码率,在模拟
施加电磁骚扰之前,观察显示器,确认系统处于正常工作状态;

d) 根据GB/T 17626.4—2008
的测量方法和场地布置进行试验,按照表8规定的等级给激励器
施加电快速瞬变脉冲群骚扰:脉冲群抗干扰模拟器连接电容耦合夹,通过耦合夹将骚扰信号耦
合到地面数字电视激励器的交流电源电缆上;

e)
4.5.5.1 要求判定激励器交流
电源端口电快速瞬变脉冲群抗扰度。

GB/T 28436—2012

5.18.5.2.2 射频共模

测量步骤如下:

a)
如图16所示连接测量系统,电磁骚扰模拟器为连续波模拟器,应使用空间发射/接收方式作为
信号传输手段,以确保地面数字电视接收机及显示器不受到所施加的射频共模骚扰信号的
影响;

b) 设置激励器工作于GB 20600—2006 规定的任意一种工作模式;

c)
设置码流发生器发送测量图像序列,码率略低于激励器此时工作模式下的最大净码率,在模拟
施加电磁骚扰之前,观察显示器,确认系统处于正常工作状态;

d) 根据GB/T
17626.6—2008的测量方法和场地布置进行试验,按照表8规定的等级给激励器
施加射频共模骚扰:连续波模拟器连接6 dB
衰减器,再通过耦合网络将骚扰信号耦合到地面
数字电视激励器的交流电源线缆上;

e)
4.5.5.1 要求判定激励器交流
电源端口射频共模抗扰度。

5.18.5.2.3 浪涌

测量步骤如下:

a)
如图16所示连接测量系统,电磁骚扰模拟器为浪涌模拟器,应使用空间发射/接收方式作为信
号传输手段,以确保地面数字电视接收机及显示器不受到所施加的浪涌骚扰信号的影响;

b) 设置激励器工作于GB 20600—2006规定的任意一种工作模式;

c)
设置码流发生器发送测量图像序列,码率略低于激励器此时工作模式下的最大净码率,在模拟
施加电磁骚扰之前,观察显示器,确认系统处于正常工作状态;

d) 根据GB/T 17626.5—2008
的测量方法和场地布置进行试验,按照表8规定的等级给激励器 施加浪涌骚扰;

e)
4.5.5.1 要求判定激励器交流
电源端口浪涌抗扰度。

5.18.5.2.4 电压跌落、中断

测量步骤如下:

a)
如图16所示连接测量系统,电磁骚扰模拟器为电压跌落模拟器,应使用空间发射/接收方式作
为信号传输手段,以确保地面数字电视接收机及显示器不受到所施加的电压跌落、中断的
影响;

b) 设置激励器工作于GB 20600—2006 规定的任意一种工作模式;

c)
设置码流发生器发送测量图像序列,码率略低于激励器此时工作模式下的最大净码率,在模拟
施加电磁骚扰之前,观察显示器,确认系统处于正常工作状态;

d) 根据GB/T17626.11—2008
的测量方法和场地布置进行试验,按照表8规定的等级给激励器
施加电压跌落、中断骚扰;

e)
4.5.5.1 要求判定激励器交流
电源端口电压跌落、中断抗扰度。

GB/T 28436—2012

A

(资料性附录)

地面数字电视广播系统净码率

地面数字电视广播系统最大净码率(8 MHz 带宽)见表 A.1。

A.1 地面数字电视广播系统最大净码率

信号帧长度

信号帧长度4200个符号

信号帧长度4375个符号

信号帧长度4725个符号

FEC码率

0.4

0.6

0.8

0.4

0.6

0.8

0.4

0.6

0.8

映射

4QAM-

NR

5.414

5.198

4.813

4QAM

5.414

8.122

10.829

5.198

7.797

10.396

4.813

7.219

9.626

16QAM

10.829

16.243

21.658

10.396

15.593

20.791

9.626

14.438

19.251

32QAM

27.072

25.989

24.064

64QAM

16.243

24.365

32.486

15.593

23.390

31.187

14.438

21.658

28.877

注:表中横线表示该模式组合不在本标准规范之内。

GB/T 28436—2012

B

(资料性附录)

电磁环境与端口

B.1 电磁环境

各类产品应用的电磁环境分为五种类别,分别对应不同的限值集,这五种类别的电磁环境描述

如下:

a) E1: 居住环境(包括GB/Z18039.1—2000 所述的1类和2类场所);

b) E2: 商业和轻工业环境(如剧院);

c) E3: 城市户外环境(依据 GB/Z18039.1—2000 的第6类场所的定义);

d) E4:
电磁兼容受控环境(如演播室或摄影棚)和乡村户外环境(远离铁路、发射机、高架电力线
等);

e) E5: 重工业环境(见 GB/T 17799.2—2003)和靠近广播发射机的环境。

B.2 端口

电磁兼容性试验中,端口是受试设备在电磁环境中的特殊界面,各端口归类见图
B.1。

B.1 设备的电磁兼容性试验端口

GB/T 28436—2012