AIX hot add FcOE card

1. Operating environment

HMC version: V7R7.3.0.1
Operating system: AIX:6100-09-06-1543
Host: IBM POWER7 750 8233-E8B (with #5802 #5877 expansion cabinet)

2. Task

Add an FCoE card (this card has two usage states)
ent0——10 Gb Ethernet-SR PCI Express Dual Port Adapter
fcs3——10 Gb FCoE PCI Express Dual Port Adapter

3. Operation

3.1 Check compatibility

https://www.ibm.com/support/knowledgecenter/8233-E8B/p7hcd/fc5708_fcoe.htm

The adapter is supported on the following versions of the operating systems:

AIX®
AIX Version 7.1 with Service Pack 3, or later
AIX Version 6.1 with the 6100-06 Technology Level, and Service Pack 5, or later
AIX Version 5.3 with the 5300-12 Technology Level and Service Pack 4, or later

Linux
Red Hat Enterprise Linux 5.6 for POWER®, or later
Novel SUSE Linux Enterprise Server Service Pack 4, or later

VIOS
VIOS support requires VIOS 2.2.0.12-FP24 SP02, or later

3.2 Configure DLPAR

If dlpar has already been configured, you can skip this step. If not, perform the following operations:
1. In the partition of the POWER host, modify the /etc/hosts file and add the IP and hostname information of the hmc
. 2. Ensure that the partition and HMC can ping each other.

3.3 Hot-adding boards in HMC

Manually add the FcOE board according to the vacant slot at the back of the machine. After confirming that everything is correct, proceed as follows:

Check the corresponding partition in HMC and select:
Insert image description here
Insert image description here

After adding, check the partition profile file and add the corresponding slot to the partition profile file.
Insert image description here

3.4 AIX, add hot-swappable card to diag

#  diag
	  Task Selection (Diagnostics, Advanced Diagnostics, Service Aids, etc.)
	  	  Hot Plug Task 
	  	      PCI Hot Plug Manager
	  	          Add a PCI Hot Plug Adapter
	  	          	  选择识别到的新槽位
	  	          	  	    新窗口中,根据系统提示,两次回车
	  	          	  	          当显示操作成功时,退出diag界面。
# cfgmgr
# lsdev -Cc adapter

Enter twice to execute

4.Add solutions to failed or unrecognized problems

The reason why I cannot identify the board is that the system has many defined devices, which occupy the slot information of the system. As a result, the system cannot recognize the newly added board device.
Just delete all defined devices to successfully add them