[Completely open source] Xiaoanpai-Remote infrared remote control

I. Overview

Xiaoanpai-Remote has a 2.4-inch LCD display module, a battery power detection module, an offline voice module, an infrared transmitter module, 8 key combination modules, a lithium battery charging module, and a DC-DC voltage conversion module.
Xiaoanpai-Remote factory firmware has made infrared adaptation to Midea air conditioner, and can control the air conditioner through buttons, touch screen and offline voice.
Anxinke M61 wireless module is used as the control core, and the 2.4-inch LCD screen is driven by the M61 chip. Each button has an independent IO input port. The offline voice communicates with the M61 through the serial port, and the battery power is detected by voltage sampling through the ADC.

insert image description here

2. System block diagram

insert image description here

3. Circuit description

3.1 2.4-inch touch LCD display

The 2.4-inch screen interface also uses the FPC cable that integrates the display + touch screen, but it uses an 18Pin interface.
insert image description here

3.2 VC voice chip

The VC-02 offline voice module uses 5V power supply, communicates with the M61 module through the serial port, and connects the speaker and microphone externally.

insert image description here

3.3 Infrared emitter

Equipped with an infrared transmitter module, which emits infrared signals to control the equipment.

insert image description here

3.4 Charging circuit

Use the USB port to charge the battery.

insert image description here

3.5 8 independent buttons

Equipped with 8 independent buttons, which are not shown here.

insert image description here

4. Offline voice list

voice command Function Reply
Xiao An Xiao An wake word how can i help you / you say
step down (exit wakeup) call me again if necessary
Turn on the air con Turn on the corresponding air conditioner air conditioner is on
turn off the air conditioner Turn off the corresponding air conditioner air conditioner is off
temperature rise Turn up the temperature of the air conditioner temperature has risen
lower temperature Lower the temperature of the air conditioner temperature has been lowered
wind speed mode Adjust the wind speed of the air conditioner wind speed changed
change mode Adjust the air conditioning mode schema changed

5. More information

Anxinke official website docs: https://docs.ai-thiner.com/remote
Jiali Chuang open source project: https://oshwhub.com/ai-thiner_openteam/aipi-remote

Guess you like

Origin blog.csdn.net/Boantong_/article/details/132456102