VW-80000-2021 edition, the latest release, (Test items, test conditions and test requirements for electrical and electronic components of vehicles below 3.5 tons
Standard automotive EMC tests such as LV124, 16750-2, VW80000, GMW3172, LV148 are essential.
The current version of the VW80000 test standard is based on the original LV (Delivery Specification) 124, which was prepared by representatives of the car manufacturers Audi AG, BMW AG, Daimler AG, Porsche AG and Volkswagen AG made.
The test items, test conditions and test requirements for electrical and electronic components of automobiles below 3.5 tons are VW80000 tests. To complete the VW80000 tests, professional equipment is often required.
VW80000 test items are as follows:
serial number | project name | Satisfactory equipment | |
1 | E-01 | long time overvoltage | EA-PS400A Automotive Electronics Programmable Power Supply |
2 | E-02 | Instantaneous overvoltage | EA-PS400A Automotive Electronics Programmable Power Supply |
3 | E-03a | transient undervoltage | EA-PS400A Automotive Electronics Programmable Power Supply |
4 | E-03b | transient undervoltage | EA-PS400A Automotive Electronics Programmable Power Supply |
5 | E-04 | Quick Start | EA-PS400A Automotive Electronics Programmable Power Supply |
6 | E-05 | load dump | EA-PS400A Automotive Electronics Programmable Power Supply |
7 | E-06 | Superimposed AC voltage (14V bias high frequency 1Vpp) | EA-PS400A Automotive Electronics Programmable Power Supply |
8 | E-06 | Superimposed AC voltage (14V bias low frequency 2Vpp) | EA-PS400A Automotive Electronics Programmable Power Supply |
9 | E-06 | Superimposed AC voltage (14V bias low frequency 3Vpp) | EA-PS400A Automotive Electronics Programmable Power Supply |
10 | E-06 | Superimposed AC voltage (14V bias low frequency 6Vpp) | EA-PS400A Automotive Electronics Programmable Power Supply |
11 | E-07a | Supply voltage drops and rises slowly (linearly) | EA-PS400A Automotive Electronics Programmable Power Supply |
12 | E-07b | Supply voltage drops and rises slowly (AC) | EA-PS400A Automotive Electronics Programmable Power Supply |
13 | E-08 | Voltage drops slowly and rises quickly | EA-PS400A Automotive Electronics Programmable Power Supply |
14 | E-09 | Voltage reset (hold time 100ms) | EA-PS400A Automotive Electronics Programmable Power Supply |
15 | E-09 | Voltage reset (hold time 5ms) | EA-PS400A Automotive Electronics Programmable Power Supply |
16 | E-10 | Power line micro-disruption (regular grade) | EA-I16 Harness Micro Interrupt Switch |
17 | E-10 | Power line micro interruption (severe level) | EA-I16 Harness Micro Interrupt Switch |
18 | E-11 | Cranking pulse (cold start normal level) | EA-PS400A Automotive Electronics Programmable Power Supply |
19 | E-11 | Start Pulse (Cold Start Severity Level) | EA-PS400A Automotive Electronics Programmable Power Supply |
20 | E-11 | Start pulse (hot start 20S hold) | EA-PS400A Automotive Electronics Programmable Power Supply |
21 | E-11 | Start pulse (hot start 5S hold) | EA-PS400A Automotive Electronics Programmable Power Supply |
22 | E-12 | Voltage curve (drop voltage 0.7V) | EA-PS400A Automotive Electronics Programmable Power Supply |
23 | E-12 | Voltage curve (drop voltage 0V) | EA-PS400A Automotive Electronics Programmable Power Supply |
24 | E-12 | Voltage curve (drop voltage 2V) | EA-PS400A Automotive Electronics Programmable Power Supply |
25 | E-13 | pin interrupt | EA-PS400A Automotive Electronics Programmable Power Supply |
26 | E-14 | connector break | |
27 | E-15 | Static reverse polarity (voltage 14V internal resistance <100mΩ) | EA-PS400A Automotive Electronics Programmable Power Supply |
28 | E-15 | Static reverse polarity (voltage 14V internal resistance <30mΩ) | EA-PS400A Automotive Electronics Programmable Power Supply |
29 | E-15 | Dynamic reverse polarity (voltage 10.8V internal resistance <100mΩ) | EA-PS400A Automotive Electronics Programmable Power Supply |
30 | E-15 | Dynamic reverse polarity (voltage 10.8V internal resistance <30mΩ) | EA-PS400A Automotive Electronics Programmable Power Supply |
31 | E-16 | ground offset | EA-PS400A Automotive Electronics Programmable Power Supply |
32 | E-17 | load short circuit | |
33 | E-18 | Insulation resistance | |
34 | E-19 | Quiescent Current | |
35 | E-20 | Dielectric strength | |
36 | E-21 | open circuit test | |
37 | E-22 | Overcurrent | EA-PS400A Automotive Electronics Programmable Power Supply |