Example of using an oscilloscope
Foreword: This article is a function record after I use the oscilloscope. It is mostly a record of common functions (I often use it, and I will add it after I use it). I write this article so that I can review and read it at any time to prevent forgetting. , other students can watch it as needed.
1. Oscilloscope pattern
I use the oscilloscope of Zhiyuan Electronics, as shown in the figure below:
The functions of the buttons on the right are explained below.
2. General introduction
The functional block diagram of the oscilloscope is as follows:
- Segmented lines, measuring the difference
A线
between and in the imageB线
, canX轴
be eitherY轴
. - Oscilloscope image stops or starts after key press
- Level-triggered capture mode
- Clear, don't know what's the use
- Automatically adjust the waveform image to the appropriate position
- Corresponding to 1,
Per
: Persistence time switch,Cur
: Switch measurement to X-axis or Y-axis,Int
: Line brightness setting - Segmentation mode, set image segmentation
- Zoom in on the mid-segment image
- Scroll mode, the waveform appears from right to left
- Zoom in or out of the overall image, adjust the time to roll over the waveform
- You can slide the overall waveform to the left and right
- Adjust the size of a single channel waveform (I understand that the specific unit of measurement should be adjusted to cause the observed waveform to shrink or enlarge)
- The waveform of a single channel moves up and down
- channel selection
- To save the oscilloscope image, you can save it to
U盘
or内置Flash
, you need to press (18 in the figure) before using itUtility
, and choose whether the saved image is saved in the U disk or Flash. - Measurement item selection display
- math operation selection
- Storage selection, you can choose to save the image location, method, save image type, etc.
- Adjust the trigger level in trigger mode
- Trigger mode setting
3. Distribution Introduction
3.1 Segmented line settings
The position of the function setting is shown in the figure:
the knob in the left frame can adjust the position of line A and line B on the image back and forth; the
button on the right can adjust the other functions of line A and line B
Persist
: after pressing it, the afterglow time will be displayed
as the picture shows
- Line A and Line B
- After pressing
Intensity
the key, the brightness of the display line is displayed - The difference between line A and line B
3.2 Single channel waveform adjustment
The functional area is shown in the figure:
Rotate ①, the image changes as shown in the figure:
It can be found that the waveform is significantly enlarged.
Rotate ②, the image changes as shown in the figure:
It can be found that the yellow waveform has moved downward as a whole.
3.3 Overall Waveform Image Adjustment
The functional area is as shown in the figure:
Rotate ①, the image changes as shown in the figure:
You can see that the overall image has shrunk.
Rotate ②, the image changes as shown in the figure:
You can see the image move to the right.
3.4 Scroll Mode
The function area is as shown in the figure:
①Select the scrolling mode
②Adjust the imagesliding time
The waveform image is as follows:
waveformright to leftmove
3.5 Measurement Display Selection
The functional area is shown in the figure:
the position shown in the figure
The oscilloscope image is as shown:
Click to select the measurement item and select the data you want to display:
Note: The selected measurement is only the display of a single channel , press ① to select the channel.
The display is as shown in the figure:
3.6 Storage options
The functional area is as shown in the figure:
after pressing, it will be as shown in the figure:
3.7 Trigger capture mode selection
The functional area is shown in the figure:
①Enable the trigger
②Adjust the trigger level
③Select the trigger capture function, as shown in the figure below:
You can choose the trigger method, trigger type, etc.
That sums it up!