How quickly the new drive (four kinds) in an existing project in the S120

Method a: Insert a new drive

Select the motor module

 

 

 Power selection module control signal, typically a choice, other models not control

 

 

 The motor Siemens motor, the motor is selected to read the data again through the Drive-Cliq interfaces; Siemens motor, but without Drive-Cliq encoder, is selected from the list; motor for a third party such as the motor, the motor data select input .

 

Motor brake control mode selection

 

 

 Select an encoder

 

Select message

 

 

 End

 

 

 Method Two: The hardware has been added new modules and motor; restore the factory settings, the online auto-configuration.

             The method in the original project will all drive configurations, the data are cleared.

 

Method three: the hardware has been added new modules and motor; a backup of the original project, save a project 2; restore factory settings in item 2, the online auto-configuration. After the automatic configuration is complete, the newly added drive module export, import in the original project backup.

    The method will be introduced in the original program a machine module, the machine module contains only configuration data automatically. Messages and other additional configuration is needed.

Export: After exporting the message contains the module configuration (not yet configured)

 

 

Import: the original project configuration messages will be imported along. (Not yet configured)

 

 

 

 

 (The same drive module, or at least the same message) to find an application in the original item in the same, or similar applications driving module;: Method four

  1, as a cu320 added at the same drive shaft, driven directly copied in the driving module, and can paste. The message will be copied along.

  2, such as adding different driving module at the CU320, the selected pilot similar drive module. The message is exported together.

  3, at the CU320 appropriate, prior to introducing the driving module exported. Message with import.

  5, such as copying or imported or motor driving module and the newly added hardware discrepancies, double-click "Configuration" in the drive module, reselection.

 

 

 The step of selecting a method which is the same; The motor with Siemens Drive-Cliq motors, motor selection reread. Compile download the configuration is complete. After the download is complete copy RAM TO ROM ---- Load to upload the PG stored.

 

 

After the automatic optimization operation.

 

 

 

    