A method of operating Altium Designer16 GND and VCC line width setting rules and precautions

Yesterday saw the school board younger brother in painting, he saw a little problem when setting up the power line width, set the rules of the role of the beginning, and later re-import updates to PCB, power cord turns green from the schematic, the rules set point updates to no avail. The next steps are:

Step one: Click the Design-Classes-Net Class-Add Class

Step two: Modify the New Class name to add, and I was set to POWER, add the need to set up a power line in, here is set up, like a point Close

Here Insert Picture Description

Step 3: Click Design-Rules-Routing-Width-New Rule, changed his name to POWER, of course, can not be set to POWER, their own free
Here Insert Picture Description

Step four: point POWER, the rules set
Here Insert Picture Description

Step five: point Priorities, the rules priority setting, the priority placed in front of the line width of the wire
Here Insert Picture Description
to the end here, like click OK, the power rules set up.
He committed two errors:
1. Update PCB, not to re-recovery rules, updated after each update must go under the rules, then remember a little in the fourth step Apply, apply this rule, or else the power cord It will turn green.
2. The rule priority setting, the fifth step, I saw his power line priority 2, after he updated wiring when the power cord has been 10mil, are powerless to change the point of step fifth picture is rule priority setting bottom left of the two options you can change the priority of.

Guess you like

Origin www.cnblogs.com/structmooc/p/11257523.html