Product introductionProduct introduction
product description
PPS synchronization accuracy tester, also known as PPS Tester, is a system clock synchronization accuracy testing equipment based on the 1PPS measurement method developed by Yi Xing Technology. It consists of hardware module ETS2110, host computer software ePPSTester and related accessories. PPS Tester supports the continuous collection and testing of 24 channels of PPS signals 24 hours a day, and the equipment test accuracy is as high as ±8ns.
PPS Tester helps evaluate the time synchronization stability of the entire system and discover unexpected bugs in the software, thereby ensuring the implementation of functional scenarios based on time synchronization.
product composition
This product consists of hardware module ETS2110, host computer and related accessories.
ETS2110 hardware
ePPS Tester host computer
● The hardware module ETS2110 is based on a high-performance fully programmable SoC chip and supports 24-channel PPS signal collection at the same time. It has extremely high sampling accuracy and a timestamp resolution of up to 4ns.
● ETS2110 uploads PPS pulse collection data to ePPSTester for processing through Ethernet, realizing real-time calculation and display of synchronization accuracy, and completing data statistics and recording
Product List
A complete set of PPS Tester consists of the following deliverables
Product HighlightsSeliing points
✔ Support 24-channel PPS signal collection
✔Support 24h continuous testing
✔ ±8ns level test accuracy
✔ Adapt to 1.8, 3.3 and 5V level input signals
✔ Real-time display of data visualization
✔ Support data recording and playback
✔ Automatically generate test reports
Application ScenarioUsage Scenario
PPS Tester is oriented to node-level and system-level clock synchronization test scenarios, and is used to measure controller clock synchronization accuracy and stability. For example, autonomous driving sensor data fusion and clock synchronization function scenarios.
Technical parameterTechnical parameter
Equipment test accuracy |
Synchronization accuracy test accuracy ±8ns |
timestamp resolution |
4ns |
Number of acquisition channels |
Route 24 |
Maximum sampling time |
24 hours |
Acquisition channel level |
The acquisition level is configurable and supports: 1.8V nominal signal: 1.8±0.15V 3.3V nominal signal: 3.3±0.3V 5V nominal signal: 5±0.5V |
Acquisition channel input impedance |
1MΩ/50Ω configurable |
Communication Interface |
Ethernet rate auto-negotiation: 100Base-Tx/1000Base-T |
Device power supply |
Working voltage: 10~15V DC Nominal voltage 12V DC Working current: max 0.5A@12V |
temperature range |
Working temperature: 0~45℃ Storage temperature: -20℃~65℃ |
Protection level |
IP31 |
size |
Length×width×height: 170mm*152mm*51mm |
weight |
The net weight of the hardware module is about 600g |