Solve the problem that Advantech PCIE-1203L cannot display the connected servo configuration window in Motion Utility

Problem Description:

When using the PCIE-1203 board, you need to use Advantech Motion Utility software to configure the parameters of the underlying server. Normally, when the PCIE-1203LAN1 port is connected to the servo, the Utility software will automatically scan the servo information and display the relevant configuration interface in the configuration interface. . However, when encountering a special brand of server, its configuration interface will not be displayed, making it impossible to set parameters for the underlying server.

system structure:

 

 Failure analysis test:

  1. Troubleshoot the driver problem, install the latest version of the control card driver, check whether the board driver is installed in the system, and find that the problem persists.
  2. To troubleshoot the network port connection problem, network port 1 of the board card is connected to the servo, and network port 2 is connected to the IO card, because only network port 1 supports the servo function.
  3. Check whether the server network port is connected properly and whether the network cable sequence is normal.
  4. After the above troubleshooting, it was found that the connection and network cable were normal, and it was suspected that it was a problem with the Motion Utility software.

Fault phenomenon:

 normal phenomenon:

 

solution:

Find the servo controller manufacturer to get the XML file of the corresponding product, and import the XML file into the folder fixed by the Motion Utility software.

 problem solved!

Guess you like

Origin blog.csdn.net/Pearflower_/article/details/130599664