Botu v17 and winCC installation process and stepping pit record

Installation Tutorial

First of all, the installation in this article is aimed at TIA portal V17 (64bit) and winCC 7.5SP2. It can be installed on both win10 and win11 systems. The following is the installation process.
First of all, you need a pure professional win system (the operating system must be a complete PROFESSIONAL version), otherwise problems may occur, and most of the suggestions for winCC installation problems are reinstallation (obtained from Microsoft's official website, GHOST, etc. will not work).
Computer name (computer name not account name) Be careful not to have special symbols (underscores are not allowed!!!), the computer name cannot be changed after installation, so pay attention to this problem before installation, otherwise the last communication software SIMATIC NET cannot be installed.
In addition, the user needs to be an administrator, not necessarily an Administrator, but an administrator.
We first install Portal, and then install winCC. Turn off "all anti-virus software (some computers have "McAfee" that comes with it), firewall, and Windows Defender of Win10 system" during the whole installation process.

Portal installation process

First introduce the TIA V17 series including

  1. TIA_Portal_STEP7_Prof_Safety_WINCC_Adv_Unified_V17 (touch screen and PLC)
  2. SIMATIC_S7-PLCSIM_V17 (simulation)
  3. Startdrive_Advanced_V17 (commissioning software)

V17 is currently a relatively stable version. First you need to get the installation package, you can refer to: yulekeji

The first step is to delete the registry

Enter regedit on the winD command line to enter the registry editor.
If you need a backup, click File\Export for backup.
Find the entry PendingFileRenameOperations in the registry path "HKEY_LOCAL_MACHINE\System\CurrentControlSet\Control\Session Manager",
right-click on the entry, select "Delete"
, otherwise the installation process may restart repeatedly

The second step is to enable the .NET Framework service

In the networked state, open: Control Panel\Programs\Enable or close windows functions , check .NET Framework 3.5. Remember to check all of them after clicking, don't just check outside.
(If you need to install winCC, check the Microsoft Message Queue (MSMQ) server at this time, and also check all of them)
Then confirm, windows will automatically update.

The third step is formal installation

Refer to the Zhihu link above

  1. First open the [SETP7+WINCCV17ADV] folder. Right-click [Siemens remove restart prompt batch processing] and select [Run as administrator]. The installation process can be done in the next step, and the software installation location can be modified in the middle. Finally, choose to restart the computer later.
  2. Open the [S7-PLCSIM17] folder, right-click [Start] and select [Run as administrator], the next step is enough, the software automatically recognizes the installation path just set, and can also be modified, it is not recommended to modify. Finally, choose to restart the computer later.
  3. Open the [Startdrive_Advanced_V17] folder, right-click [Start] and select [Run as administrator], as above.
  4. Open the [TIA portal V17 (64bit)] folder after the installation package is decompressed, right-click [Crack] and select [Extract to current folder]. Right-click the decompressed [Crack] and select [Run as administrator].
    ❶ Double-click [TIA Portal], ❷ double-click [TIA Portal V17], ❸ select [Single Authorization at Workplace], ❹ check (marked in the figure, select all), ❺ click [Install Long Key].
    process
    A prompt will appear, and then the long name column will turn blue, indicating success.
    result

Exit the software at this time, double-click the [TIA Portal V17] icon on the desktop to start the software, and the installation is successful.

winCC installation process

It is recommended to download from the official website. The link to the official website is http://www.wincc.com.cn/rjzsk.aspx?type=2, which needs to be registered before downloading.
After downloading, decompress five files, and then decompress the 001 file (it is recommended to use 7zip to decompress), enter the decompressed file, and right click to load. After loading, a drive disk directory will be added under the disk, click to enter and select setup.exe to install. Prompt to choose restart. reload.
At this time, if you need to install SIMATIC NET (communication driver), you can try to load and install SIMATIC NET in the five files. After installation, install winCC. The whole process can be downloaded and installed
according to the official website of wincc7.5 (adapted to the super detailed tutorial of window10). The same applies to win11.

Botu v17 and winCC installation records

The personal computer is Win10 Professional Edition.
Generally, Portal is installed first. Before installation, a value needs to be deleted from the registry. .NET Framework needs to be updated on Windows. (winCC needs the message queue server to also enable updates in the same place, remember to check all of them, don't just check outside [I suspect that my problem is caused by not starting all here]) Then follow the Zhihu link https:
// www.zhihu.com/tardis/sogou/art/527846016 Just install it.
winCC is 7.5SP2, it should install the advanced version, normally you need to refer to the two versions of the tutorial, the first choice is https://blog.csdn.net/qq_40715266/article/details/120772566, in addition to the three-step tutorial in the folder, when you try it for the first time Install according to the three-step installation tutorial, modify the computer account (in fact, it should not be necessary), and try to open the project after installation, it prompts that the project creation version is higher than the current version, so it cannot be opened. Trying to create a new project, it prompts that the server cannot be connected.
insert image description here
Inquire about the cause of the problem,

  1. There may be a problem with the installation, or the database may not be installed properly.
  2. To modify the value of EnableDCOM under \HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Ole in the registry is Y.
    But modified.
  3. It may be that the authorization is not working, so try to re-authorize.
    Re-authorization is still not possible, and the lower right corner of the software shows the authorized mode, so it is excluded.
  4. PC name do not use Chinese and the horizontal bar
  5. Do not change the computer name after installing WinCC.
    If you plan to reinstall, first refer to this link https://blog.csdn.net/qq_40715266/article/details/120772566.
    First, uninstall through HiBit Uninstaller, select the six files with winCC in the name, and leave SIMATIC WinCC Runtime Advanced V17.0, because it feels like it was installed together with Botu in the last wave. Check and find that the Simatic Shell folder in this computer does not exist anymore, it should be deleted very cleanly, download and reinstall. Register official website account to download 7.5SP2

After configuring and cracking the authorization according to the method of https://blog.csdn.net/qq_40715266/article/details/120772566, the new project fails, and the following prompt Please add a picture description
fails to open the existing project, and the error is reported as follows.
Please add a picture description
Choose to start the local server, and report an error after loading for a while The following
Please add a picture description
query problem may be that the server computer name is different, you need to change the local server name to my computer name.
Because the project cannot be opened, it cannot be changed, only reinstalled. This time I decided to unload SQL as well.
uninstall report

Please add a picture description

Please add a picture description
After reinstalling this time, a new project can be created. Although there is still something wrong, the problem is not big.
It will still say that the server is unavailable. This time, you can right-click on the computer on the left side of the project and change the server name to the local computer name.
The cracking of the hardware dog is invalid. I downloaded a new one and put it in the folder. When decompressing, the computer will automatically delete it. Go to the firewall to set it up and crack it. Completely resolved.

Win11 Home Edition

The application method successfully installed Portal, and the winCC installation is also normal, but after opening the new project, an error will be reported "The service did not respond to the start or control request in time". Query http://www.zhumeng.org/thread-128230-1-1.html
and suddenly remembered that I forgot to install the fourth step of network communication, so install it quickly.
After installing it, it still doesn’t work. After consulting the official website of Siemens, it is judged that the home version should not work. You need to upgrade the system to the professional version first.
After upgrading the professional version, it prompts the question of user rights. Although the user has administrator rights, it needs to be added to winCC operation rights, so modify the user group.
The project can be opened, but it is very slow, and then it prompts the problem of needing USB hardware and local server that has appeared before. The project can be opened after modification, but both runs are stuck at the same progress bar. (Tag Logging Runtime - Initializing archive management 50%)The interface where the progress bar is stuck for ten minutes

After uninstalling and reinstalling, the wrong computer name is reported when installing SIMATIC NET, so the computer name must not be underlined. As shown in the picture.
Please add a picture description
Now if you change the computer name, the previously installed Portal and winCC will also have problems. Don't install this first, and find that it can be opened and run. If SIMATIC NET is not installed, there may be problems connecting to the PLC, and then check again when communicating. If not, uninstall or reinstall the system completely.
https://www.ad.siemens.com.cn/productportal/prods/hmi/wincc/q8_faq/wincc_simatic_net_note.html