Motion camera to capture the human face appears fuzzy

If that ISP inside the camera module is generally AE Exposure default exposure time priority, motion blur problem can occur when capturing moving objects, and for facial capture machine, high-quality facial images for subsequent face detection, face recognition, etc. function has a significant impact.
Here Insert Picture Description
The content is presented in Figure "digital photography practice" in a book made for motion blur problems instructive.
In practical tests, lack of room light exposure in accordance with the default policy (to adjust the exposure time ET, ET = 40ms after exposure amount of the screen is still not the case, the gain value, the strategy is to reduce the noise) Exposure time ET about 35ms, capture a pedestrian, when a camera to capture the distance (6mm focal length) of about 2 meters per pedestrian line motion blur occurs, the pedestrian 2 meters outside the basic motion blur does not occur;
adjusted to 10ms ET manually, increasing the gain later, the same capture pedestrian, the pedestrian when the distance from the camera (6mm focal length) of about 2 m to capture motion blur occurring pedestrian will be improved, but for people to walk or slightly faster motion blur;
adjusted manually to 8ms ET , to capture pedestrian motion blur does not occur again (based on the current test set), the data corresponding 8ms 1 / 125s mentioned in the book, is the same;

So for the capture of moving objects, to minimize exposure time, otherwise there is motion blur, of course, to have a motion blur algorithm can also be processed.

Guess you like

Origin blog.csdn.net/lovexiao0106/article/details/92571551