Levi Monitoring | How to quickly close all ports of network equipment

In the practice of operation and maintenance monitoring, since different operation and maintenance personnel may pay attention to different monitoring indicators, Lewei Monitoring will open all ports by default when monitoring network devices, covering as many monitoring indicators as possible to avoid missing important indicators . However, this will bring new problems. In some operation and maintenance scenarios, some "irrelevant" ports will frequently generate "UP/DOWN" alarms, resulting in failure to achieve the expected alarm effect.

Based on the different demands of different users for monitoring indicators, between large and comprehensive monitoring indicators and few and precise monitoring indicators, Lewei gives users the former by default, and users can remove unnecessary indicators from all monitoring indicators.

This article will introduce how Levi Monitor disables all the ports of network devices, and the operation and maintenance personnel can open and monitor the core ports according to actual needs during subsequent use. The following are the specific steps:

1. Find the template that needs to be adjusted under [Acquisition Manager]-[Template Management]. The following template is an example: 2.
insert image description here
Click on this template and click the "Full Clone" button
insert image description here
3. Need to adjust the [Template Name] and [Visible Name] ] (the name of the original template cannot be exactly the same), click the "Add" button insert image description here
4. The new template has been generated, and the new template needs to be migrated. Please refer to Template Migration-Object Migration (lwops.cn)

insert image description here
5. Click [Auto Discovery] of the new template

insert image description here
Click the prototype of the monitoring item named "Port Table UP" ("Port Table DOWN" also needs to perform the same steps),
insert image description here
select all monitoring items, and click the [Batch Update] button ("Port Table DOWN" also needs to perform the same steps)
insert image description here
Check [Enable New], click [No], and then click the [Update] button ("Port Table DOWN" also needs to perform the same steps) the effect is shown in the figure below: 6. Click the [Host] of the insert image description here
original insert image description here
template

insert image description here
Check all the hosts under the original template, click [Batch Update],
insert image description here
check the [Template Link], click the [Replace] button, then select the newly cloned template, check [Clear when there is no link], and finally click the [Update] button That's it
insert image description here
7. The hosts in the original template have been linked to the new template. insert image description here
8. The final effect is shown in the figure below. All ports have been disabled by default, and subsequent operation and maintenance personnel can open the ports they care about.
insert image description here
insert image description here
The above is the sharing content of this issue. Hello everyone, I am Lele, focusing on the research and sharing of operation and maintenance technology. Follow me to learn more about operation and maintenance knowledge. If you have any questions, you can also leave a message in the Lewei community to ask questions, share and communicate with the majority of operation and maintenance technology enthusiasts.