Embedded ~PCB Album 5

Only PCB-related 5 will be updated at any time~~ whaosoft  aiot  http://143ai.com  

1. Inductive howling countermeasures

I feel like it has something to do with it, so I put it here

  When laptops, tablets, smartphones, TVs, and in-vehicle electronic devices are running, a "cheeping" noise is sometimes heard. This phenomenon is called "howling".

    The cause of this phenomenon may lie in passive components such as capacitors and inductors. The principles of howling generated by capacitors and inductors are different. Especially the howling of inductors has various and complicated reasons.

    This article introduces the causes of howling in power inductors and effective countermeasures.

Causes of Power Inductor Whistle

1. Intermittent work, variable frequency mode, load changes, etc. may cause audible frequency vibrations to the human ear

    Sound waves are elastic waves that propagate in the air, and human hearing can hear "sound" in the frequency range of about 20-20kHz. In the power inductor of a DC-DC converter, when an alternating current or a pulse wave of a frequency within the audible range of the human ear flows, the main body of the inductor vibrates. This phenomenon is called "coil noise" and is sometimes heard into a howling phenomenon (Figure 1).

   ​Picture 1 above

    As the functions of electronic equipment continue to increase, the power inductor of the DC-DC converter has also become one of the sources of noise. In DC-DC converters, switching devices are turned ON/OFF to generate pulsed current. By controlling the length of ON time (pulse width), a stable DC current with constant voltage can be obtained. This method is called PWM (Pulse Amplitude Modulation), and it is widely used as a mainstream method of DC-DC converters.

    However, the switching frequency of the DC-DC converter is relatively high, reaching several 100kHz to several MHz. Since the vibration at this frequency exceeds the audible range of the human ear, no noise will be felt. So, why does the power inductor of the DC-DC converter emit a "squeak" howling?

    There are several possible reasons. The first possibility is that the DC-DC converter is intermittently operated for the purpose of saving battery power, or the DC-DC converter is switched from the PWM method to the PFM (Pulse Frequency Modulation) method. The case of operation in variable frequency mode. Figure 2 shows the basic principles of PWM and PFM.

 

Figure 2 above: PWM (Pulse Amplitude Modulation) mode and PFM (Pulse Frequency Modulation) mode.

2. Howling caused by intermittent operation of DC-DC converters such as PWM dimming

    For the purpose of saving energy, etc., the automatic dimming function of the backlight of the liquid crystal display of the mobile device has introduced intermittent operation of the DC-DC converter. This is a system that automatically adjusts the brightness of the backlight according to the illuminance of the usage environment to extend the battery life.

    There are many ways for this dimming, among which, the way of controlling the LED lighting time and the length of the light-off time is called PWM dimming. The advantage of the PWM dimming system is that there is less chromaticity change caused by dimming, and it is mainly used in the backlight of notebook computers and tablet computers.

    PWM dimming makes the DC-DC converter intermittently operate at a low frequency of about 200Hz, and adjusts the brightness by repeatedly turning on/off the light. In a constant on/off cycle, turning the light on longer will make it brighter and shorter it will make it darker. In the intermittent work of around 200Hz, the eyes will basically not notice the strobe of the backlight. However, since it is at a frequency audible to the human ear, when an intermittently operating current flows through a power inductor mounted on a substrate, the main body of the inductor will vibrate due to the frequency, resulting in howling.

    Duty cycle:

    In a DC-DC converter, the ratio of the ON time to the switching cycle (ON time of the switching device + OFF time) is called the duty ratio. When performing PWM dimming on LEDs, the lighting time/(lighting time + light-off time) is called the duty cycle and represents the brightness.

3. Howling caused by frequency variable mode DC-DC converter

    The characteristic of the PWM method DC-DC converter is that its efficiency can be as high as about 80~90% in normal operation. However, under light load conditions such as standby time, the efficiency will be seriously reduced. Losses due to switching are proportional to frequency. For this reason, constant switching losses occur at light loads, thus reducing efficiency.

    Therefore, in order to improve this problem, a DC-DC converter that automatically replaces the PWM method with the PFM (Pulse Frequency Modulation) method is used under light load conditions. The PFM method is a method of controlling the switching frequency with a fixed ON time in accordance with load reduction. Since the ON time is constant, the switching frequency will gradually decrease by extending the OFF time. Since switching loss is proportional to frequency, efficiency can be improved at light loads by lowering the frequency. However, the reduced frequency will enter the range of about 20~20kHz that can be heard by the human ear, and the power inductor will whistle at this time.

4. Howling caused by load

    Various power-saving technologies are used in mobile devices such as notebook computers for the purpose of saving battery power, which may cause inductors to whine. For example, for the purpose of both low power consumption and processing power, there is a mode of periodically changing the current consumption in the CPU of a notebook computer. When the cycle is in the frequency range audible to the human ear, the power inductor may be affected Produce howling.

    The role of power inductors in DC-DC converters:

    Inductors allow direct current to flow smoothly, and for changing currents such as alternating currents, an electromotive force is generated in a direction that prevents the change through self-induction and acts as a resistance. At this time, the inductor converts electrical energy into magnetic energy, accumulates it, and releases it after converting it into electrical energy. The magnitude of this energy is proportional to the inductor inductance.

    Power inductors, also known as power coils and power choke coils, are the main components used in switching power supply circuits such as DC-DC converters. By coordinating with capacitors, the high frequency generated by switching devices ON/OFF Pulses are smoothed out.

    Since a large current flows through the power inductor of the power supply circuit, the winding type is the mainstream product. This is because, by using a magnetic material with high magnetic permeability (ferrite or soft magnetic metal) in the core, a high inductance value can be realized with a small number of windings, and the product can be further miniaturized. Figure 3 shows the basic circuit of a DC-DC converter (non-isolated type and chopper type) using a power inductor.

Figure 3 above: The basic circuit of a DC-DC converter (non-isolated type and chopping method).

Mechanism of Power Inductor Body Vibration and Noise Amplification

    When a current with a frequency in the audible range of the human ear flows, the vibration generated in the main body of the power inductor will cause howling. There are several possible reasons for the vibration and noise.

    Cause of vibration
    ➀ Magnetic core magnetostriction (magnetic strain) action
    ➁ Magnetic core magnetization causes mutual attraction
    ➂ Leakage flux causes winding vibration

    Causes of noise amplification
    ➀ Contact with other components
    ➁ Effects on surrounding magnetic bodies due to leakage flux
    ➂ Same as the natural vibration number of the entire assembly including the substrate

    Figure 4 summarizes the vibration causes and noise amplification causes of power inductor howling. The main contents of these reasons are explained below.

   ​Picture 4 above

Various causes and effects of vibration

Vibration cause 1: Magnetic core magnetostriction (magnetic strain)

    When a magnetic body is magnetized by applying a magnetic field, its shape changes slightly. This phenomenon is called "magnetostriction" or "magnetic strain". In an inductor with a magnetic core such as ferrite, the AC magnetic field generated by the winding expands and contracts the magnetic core, and vibrations may be detected.

  ​Picture 5 above

    Magnetic bodies are collections of small areas called domains (Figure 5). The magnetic moments of the atoms inside the magnetic domain are in the same direction, so the magnetic domain is a tiny magnet with a constant spontaneous magnetization direction, but the magnetic body as a whole does not exhibit the characteristics of a magnet. This is because the plurality of magnetic domains constituting the magnetic body are arranged so that spontaneous magnetization cancels each other out, and thus appear to be in a demagnetized state.

    When a magnetic field is applied to the magnetic body in this demagnetized state from the outside, the spontaneous magnetization direction of each magnetic domain is unified to the direction of the external magnetic field, so the range of the magnetic domain gradually changes. This phenomenon is caused by the movement of magnetic walls, the boundaries between magnetic domains. Thus, as the magnetization proceeds, the dominant magnetic domain gradually expands its range, and finally becomes a single magnetic domain, facing the direction of the external magnetic field (saturation magnetization state). In this magnetization process, a minute positional change occurs at the atomic level, but at the macroscopic level, it appears as magnetostriction, that is, a change in the shape of the magnetic body.

    The shape change caused by magnetostriction is extremely small, about 1/10,000 to 1/1,000,000 of the original size, but as shown in Fig. When the magnetic field is alternating, the magnetic body will expand and contract repeatedly and generate vibration. For this reason, in power inductors, the vibration of the magnetic core due to magnetostriction cannot be completely eliminated. Although the vibration level of a single power inductor is small, when it is mounted on a substrate, if its vibration is consistent with the natural vibration number of the substrate, the vibration will be amplified, and howling will be heard.

Vibration cause 2: Magnetic core magnetization leads to mutual attraction

    When a magnetic body is magnetized by an external magnetic field, it will exhibit magnetic properties, thereby attracting each other with surrounding magnetic bodies. Figure 6 shows an example of a fully shielded power inductor. This is a power inductor with a closed magnetic circuit structure, but there is a gap between the drum core and the shield core (ring core), and noise may be emitted from there. When an alternating current flows through the winding, the magnetized drum core and shield core will attract each other due to the magnetic force generated by the generated magnetic field. If the vibration is within the audible frequency range of the human ear, noise will be heard.

    The gap between the drum core and the shield core is sealed with an adhesive, but in order to prevent cracking due to stress, no hard material is used, and vibration due to mutual attraction cannot be completely suppressed.

  Figure 6 above: The drum core and the shield core are attracted to each other, resulting in howling.

Vibration cause 3: Winding vibration due to leakage flux

    In an unshielded power inductor without a shielded core, there will be no howling due to the mutual attraction caused by the magnetization of the drum core and the shielded core mentioned above. But other problems can occur in unshielded products. Since the unshielded product has an open magnetic circuit structure, the leakage flux will affect the winding. Due to the current flowing in the winding, a force acts on the winding according to Fleming's left hand rule. For this reason, when an alternating current flows through the winding, the winding itself vibrates, causing howling (Fig. 7).

  ​Picture 7 above

Various causes of noise amplification

Noise Amplification Cause 1: Contact with Other Components

    In a power circuit board on which many electronic components and devices are mounted at high density, if the inductor comes into contact with other components, the tiny vibration of the inductor will be amplified, and howling will be heard.

Noise amplification reason 2: Leakage flux causes effects on surrounding magnetic bodies

    When there is a magnetic body such as a shield near the inductor, the magnetic body will vibrate due to the influence of the leakage flux of the inductor, and howling will occur.

    Noise amplification reason 3: The natural vibration number is the same as that of the whole component including the substrate. Normally, the air vibration caused by the magnetostriction of a small magnetic body core used in products such as inductors is basically not affected by it. identified as howling. However, the inductor is composed of multiple components, and when it is mounted on the substrate, it will generate natural vibration numbers of multiple audible frequencies of the human ear, and the vibration will form a howling after the vibration is amplified. At the same time, if it matches the multiple natural vibration numbers of the whole module, howling may occur after being installed in the module.

    Figure 8 shows an example of analyzing the vibration of a board on which a power inductor is mounted using a computer simulator using FEM (Finite Element Method). In the analysis model used, the power inductor is placed in the center of the substrate (FR4), and the two long sides of the substrate are fixed.

    In general, there are multiple natural values ​​(natural vibration numbers) at which a structure resonates, and accordingly, there are various vibration modes. In this "power inductor + substrate" analysis model, as the frequency increases, various vibration modes appear for each natural vibration number. In the 1st, 2nd, 5th, and 18th vibration modes shown in Figure 8, the power inductor may be the source of the vibration. Among them, the vibration frequency of the primary mode is basically the same as the vibration frequency of a single power inductor. However, it is worth noting that the secondary mode, which vibrates significantly in the Z direction (height direction), appears at a high frequency in the case of a single power inductor, but appears at an extremely low frequency when it is fixed on a substrate.

    《Analysis model》The power inductor is placed in the center of the substrate (FR4).

    Boundary conditions: 2 sides of the long side of the fixed substrate.

1 mode: 2034Hz

 2nd mode: 2262Hz

 5 times mode: 4048Hz

 18 mode: 16226Hz

 

    Figure 8 above: An example of analyzing the vibration of "power inductor + substrate" with a computer simulator.

Noise Countermeasures for Power Inductors

    The following summarizes the key points for countermeasures against noise from power inductors in DC-DC converters.

Key point 1: Avoid flowing current at audible frequencies to the human ear

    Avoiding the flow of audible frequency current to the human ear is the most basic countermeasure.

    However, if it is unavoidable to conduct electricity at frequencies audible to the human ear, such as intermittent operation for the purpose of energy saving, etc., or a DC-DC converter in variable frequency mode, try the following noise reduction measures.

Key point 2: Do not place magnetic objects around

    Do not place magnetic objects (shields, etc.) that may be affected by leakage flux near the inductor. If it is necessary to approach it as a last resort, use a shielded (closed magnetic circuit structure) inductor with less leakage flux, and pay attention to the placement direction.

Key point 3: Stagger the natural vibration number

    Sometimes the howling can be reduced by staggering the natural vibration number or increasing the vibration number. For example, by changing conditions such as inductor shape, type, layout, and substrate fastening, the natural vibration frequency of the entire package including the substrate will change. In addition, howling is common in large power inductors with a size of 7mm or more. By adopting a small power inductor of 5mm or less, the natural vibration frequency will be increased, thereby reducing howling.

Key point 4: Replacement with metal integral molding type

    As mentioned above, in a fully shielded power inductor, the drum core and the shield core are magnetically attracted to each other, and noise occurs in the gap. Meanwhile, in unshielded type power inductors, vibration of wires caused by leakage flux can cause howling.

    Replacing this type of power inductor with a metal one-piece molded type is an effective solution to the noise problem of such power inductors. This is a power inductor that is integrally molded by embedding an air-core coil in soft magnetic metal powder. Since there is no gap, the magnetic cores will not attract each other. At the same time, since the coil is integrated with the magnetic body when fixing the coil, the problem of winding vibration due to magnetic flux can also be avoided. Not only that, TDK's products also use metal magnetic materials with low magnetostriction, so vibration caused by magnetostriction can be suppressed, and it is expected to reduce howling by replacing unshielded or fully shielded products.

Guess you like

Origin blog.csdn.net/qq_29788741/article/details/131354283