Response measures for data center integrated wiring operation and maintenance under the epidemic

The Wuhan epidemic has not yet ended. Many companies have started operations, and some companies still maintain online offices. The epidemic has caused a great impact on many industries, especially catering and other industries that have been hit hard. So what impact will it have on the data center industry, especially the integrated wiring operation and maintenance work in the data center infrastructure? The summary is as follows:
1. Failure handling is not timely.
2. If one person is infected, everyone needs to be quarantined, including security and cleaning.
3. The shelf rate increases, and the infrastructure operation and maintenance cannot keep up.
4. Hope to manage remotely.
5. The demand for robots will increase in the future.

During the epidemic, most companies chose the AB position system, which is equivalent to changing from the original 10 people to 5 people, which will inevitably increase the difficulty of the work, the time for troubleshooting is not timely, and the probability of failure will increase accordingly. . If one person is infected at this time, the operation and maintenance personnel of all the doors may face isolation, but the basic operation and maintenance work such as equipment loading and unloading will not stop, which is why the infrastructure operation and maintenance work cannot keep up. .

Based on these conditions, in this special period, many industry experts and business leaders have put forward the hope that most of the basic operation and maintenance work can be remotely managed, including remote work in normal work after the epidemic in the future. First; it can reduce corporate office costs, increase revenue and reduce expenditure; second; employees can also do their own work while taking care of more personal, family and life matters; doing a good job in protection and minimizing personnel density is what we must always pay attention to in the future thing. Some people have proposed to use robots to replace more human work. Personally, this is also an important trend in the future.

In view of the above-mentioned assumptions, the visualized operation and maintenance management platform of Navdi's computer room equipment and lines can not only realize all of them but also many other functions. The main reason for the failure to handle the fault in time is because the basic data is inaccurate or missing. Another reason is that the time for troubleshooting is not timely enough because of the complicated search time of the line connection. The biggest advantage of the Navedi data center equipment and line visualized operation and maintenance management platform is that it can realize the connection between the equipment ports and automatically generate the topology map of the link. The data and scenes of the software platform are truly consistent with the current situation in the computer room, which also provides raw data for robot operations, which is the prerequisite foundation for robots to replace human work. At the same time, remote office is achieved. Because the content of the platform is consistent with the existing computer room, the operation and maintenance personnel can survey and plan information on the platform. After the planning is completed, a work order is automatically generated and sent to the implementation personnel or robots, reducing on-site surveys And document the two steps after implementation. While saving time and improving the efficiency of operation and maintenance, accurate data records are also available. The process-based operation and maintenance management concept implemented in online planning and offline implementation improves work efficiency and has a clear division of responsibilities. There are accurate records on the platform who does the planning and who implements it. In addition, for data center operation and maintenance work, document management, asset management, capacity management, change management, and event management of important data can also be realized.

Insert picture description here
Insert picture description here
The supplementary functions are as follows:

  1. Space resource management
  • The system adopts B/S architecture, and the client does not need to install software;
  • The system supports the creation of links between scenes, devices, boards and ports in a visual way;
  • Display the computer room space in graphical visualization, support the import of CAD\VISIO\KMZ files, the export of PDF\PPT\HTML files, support the static JGP\PNG\GIF\SVG format, and support dynamic GIS maps;
  • Display the available cabinet space in a graphical and visual manner, and at the same time support report statistics such as cabinet available space and used space;
  • Display available ports in a graphical and visual manner, and support report statistics such as available ports and used ports of equipment;
  • Display the space occupancy of outdoor tube wells in a graphical and visual manner, and support report statistics for available tube wells and other data;
  • Display the pipeline in a graphical and visual manner, and support report statistics such as pipeline information, pipeline space occupancy rate, and optical cable data volume in the pipeline;
  • Display fiber use information in a graphical and visual manner, and support report statistics such as the number of available fibers and the number of used fibers;
  • Manage and track wire ducts and overhead bridges under the floor of the computer room in a graphical and visual manner.
  1. Equipment resource management
  • Pre-define the visualization model of IT equipment of major brands, at least >5000, and it is convenient to customize the equipment model;
  • The device model can customize the port according to different models;
  • For slot-type devices, the model can customize the slot according to different models;
  • Integrate common monitoring protocol SNMP, etc., which can collect equipment related data in real time;
  • Can arbitrarily define extended device attributes to accurately describe device related information;
  • Support device log tracking;
  • The device information can be used to quickly locate the device and query the device connection relationship;
  • Support multi-dimensional statistics of equipment information such as brand, model, and business type;
  • Support equipment document management to facilitate the electronic management of equipment-related documents;
  • Support the import of EXCEL equipment data.
  1. Transmission network resource management
  • It can record and manage the connection between the network physical layer and the application layer, and can create associations between layers.
  • Network layer connections can be automatically discovered and documented.
  • Record SDH, SONET, Ethernet, DWDM and other links, including complete hierarchy and branches.
  • Can map low-level links to higher-level containers (such as T1 to T3, T3 to OC-3, etc.).
  • The system that supports the main path and multipath automatically recommends the selection.
  1. Optical cable network resource management module
  • Visualize outdoor wells, pipelines, pipe trenches and outdoor communication components and routing.
  • Supports the creation and management of optical cable elements such as optical fibers, optical cables, and splice trays, and visually connects indoor and outdoor communication interfaces.
  • The fiber core and the optical cable, and the optical cable and the pipeline can be associated and bundled, and they can be arranged on the outdoor GIS map according to the actual route.
  • Can record radio and wireless equipment and their links (towers, antennas, radio equipment and related circuits and frequencies).
  • Quickly inquire about various IT equipment and any type of cables in the computer room or wiring closet.
  • Supports custom modeling of various types of cables and equipment.
  • Unlimited customization of any attributes of the cable, including type, connector, length, use department, color, etc.
  • Visualize port-to-port connections.
  • Customize the cable color.
  • You can view any level of connection: ports, boards, equipment, cabinets, buildings, parks, etc.
  • Visually track the fiber from the switch to the patch panel and any jumps between them.
  • End-to-end link tracking of each fiber or copper cable.
  • It supports the association and bundling of optical fibers, optical cables, pipes, and pipe trenches.
  • Supports custom bending points and precise adjustment of cable routing at any level of accuracy.
  • Support the use of unlimited custom attributes and rules to model various power lines.
  • Track any attribute of the power cable, including any number of custom fields such as type, current intensity, length, etc.
  • The color of the power plug and cable can be customized to show the power connection.
  • Create power supply circuit layout records for end-to-end tracking of each power supply.
  • Support measuring the length of optical cable.
  1. Resource Early Warning Management Module
  • Integrate common network management protocol SNMP, etc., which can collect equipment related data in real time;
  • It can set the U position of the cabinet, the threshold of the equipment port occupancy rate, and the early warning of resource utilization rate
  • Automatically track the occupancy rate of bridges and pipes and customize the filling rate equation. Based on the current filling rate threshold, dynamically adjust the color of the bridge frame to warn the resource usage rate;
  • If the threshold is exceeded, an alarm will be triggered, and the alarm will be notified via email or SMS.
  1. Query statistics module
  • Users can customize expressions through SQL scripts and count object data according to their needs;
  • Users can customize tables through SQL scripts as needed to generate statistical reports;
  • The integrated visual report engine allows unlimited custom visual reports according to actual needs.
  1. System Management
  • User management: support user information management, can query user online status and audit trail user login log;
  • Group management: support user grouping, different groups can set different area access permissions;
  • Authority management: supports user authority above level 6;
  • Log management: Detailed log records for user operations, and report analysis of logs;
  • Display settings: the number of data records displayed on the page, the default page size and color can be set;
  • Supports common application program interfaces such as RESTful to facilitate docking with other application systems.
  1. application server
  • CPU: 4-core 2.0GHz+
  • Memory: 16G+
  • Hard Disk: 500GB+
  • Minimum RAID requirements for disks: RAID 5
  • Insert picture description here